Guideline for Numerical Electromagnetic Analysis Method
Publications associées (268)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Recent power quality studies have been focused on the source-identification of voltage disturbances at distribution network busses. This paper describes a method aimed at correlating indirect-lightning events with power systems relay operations, associated ...
We discuss the formulation, validation, and parallel performance of a high-order accurate method for the time-domain solution of the three-dimensional Maxwell's equations on general unstructured grids. Attention is paid to the development of a general disc ...
The appraisal of the response of distribution networks to the excitation of lightning electro magnetic pulse (LEMP) requires the availability of accurate models of LEMP-illuminated lines. These models should be able to take into account the presence of shi ...
This paper presents a new approach to model a transmission tower for lightning performance studies. It consists of representing each part of the tower by equivalent vertical and/or horizontal transmission lines as required. While horizontal line parameters ...
Lightning currents and electromagnetic fields associated with return strokes to elevated strike objects The aim of this thesis is the modeling of lightning return strokes impacting elevated strike objects such as towers. The theoretical and experimental wo ...
Power line communication (PLC) is a well-known technique for data transmission over low-voltage power lines. The PLC signals have frequency bandwidth of about 1-30 MHz and they may cause electromagnetic interferences with services operating in the same fre ...
In the last twenty years, the widespread use of sensitive electronic devices has increased the interest in transients, in particular those caused by lightning (direct and/or indirect). This paper presents the latest developments in modeling the electromagn ...
While most of the emphasis has been focused on the radiated threat represented by intentional electromagnetic interference, it is clear that the threat from conducted disturbances should not be neglected. Conducted threats include those that are produced b ...
We discuss in this paper the influence of the height of an elevated strike object on the magnitude of lightning radiated electric and magnetic fields. For the analysis, the transmission line (TL) return stroke model for the lightning channel is adopted and ...
The statistical assessment of the lightning-performances of distribution lines must take into account the presence of protection devices such as surge arresters and shielding wire/neutral groundings. Indeed, the presence of those devices does modify the in ...