Dynamic flow control and performance comparison of different concepts of two-phase on-chip cooling cycles
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Rising chip temperatures and aggravated thermal reliability issues have characterized the emergence of 3D multiprocessor system-on-chips (3D-MPSoCs), necessitating the development of advanced cooling technologies. Microchannel based inter-tier liquid cooli ...
Magnetic refrigeration is a new environmentally benign technology and a promising alternative to conventional vapor-cycle refrigeration. Among these technologies the household refrigerator without a freezing compartment shows very good prospects for a succ ...
Three micro-evaporator cooling cycles, one with a pump, one with a compressor and a hybrid of the two together, are proposed for cooling a computer blade server. The hybrid cycle is characterized by the interchangeability between the first two cycles, wher ...
This report presents the work done in the frame of a Minor in Energy project in the school of Mechanical Engineering at the Swiss Institute of Technology of Lausanne (EPFL), in order to obtain 10 ECTS credits. It is to install, instrument and test an exhau ...
An end-wall cooling geometry with both fan-shaped and cylindrical holes is tested. The test case is composed by a linear cascade with cylindrical blades, the cooling holes disposed over eight rows. Each row is disposed along iso-Mach lines to ensure same b ...
The application of flow boiling in microchannels in copper cooling elements for very high heat flux dissipation from microprocessor chips is one of the promising technologies to replace air cooling and water cooling of these units, particularly in mainfram ...
The analysis of cooling of a binary HTS 20 kA current lead (CL) operating between 4.5 and 300 K has been carried out. Assuming that the HTS module is conduction-cooled, two cooling options for the copper heat exchanger (HEX) part of the CL have been consid ...
Experimental results on the fire endurance of full-scale glass fiber-reinforced polymer (GFRP) composite columns are reported in this paper. The pultruded four-cell profiles were first loaded to axial compression (uniform serviceability stress of 5 MPa) an ...
Increasing economic development, and growing population, generated during the last decades a very important growth of cities. Urban regions include nowadays more than half of the global population and, by 2030, this proportion is forecasted to increase to ...
Structural fire endurance experiments were conducted on full-scale cellular glass fiber reinforced (GFRP) columns under axial compression and subjected to ISO 834 fire exposure from one side. Unprotected columns could resist fire for more than 30 min, whic ...
Springer-Verlag New York, Ms Ingrid Cunningham, 175 Fifth Ave, New York, Ny 10010 Usa2010