Analysis of the CICC Performance Through the Measurement of the Thermal Strain Distribution of the Nb-3 Sn Filaments in the Cable Cross Section
Publications associées (65)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Current reconstruction in cable-in-conduit conductors (CICC) cables is a crucial issue to determine cables performance in working conditions, and must be performed using inverse problem approaches as direct measurement is not feasible. The current distribu ...
The index n of the voltage-current characteristic of large superconductors is a crucial parameter to assess the allowed range for coil operation. In the tests of the Insert coils at the CSMC as well as in the short sample test in the SULTAN facility, it is ...
The experiments of Cable-in conduit conductor (CICC) short samples with high proportion of segregated copper strands have been carried out in SULTAN facility last September. These experiments aimed to investigate transient stability and AC losses of CICC c ...
For large cable-in-conduit conductors, a current unbalance among the strands may be the reason for reduced performance in both de and pulsed operation, The resistance distribution of the strands at the conductor termination has been investigated as the kev ...
Linear alkylbenzene (LAB) cable oils are used for the electrical insulation of high-voltage underground power cables. Due to thermal movement of the cables, leaks can occur at the joints, resulting in cable oil leaking into the surrounding environment. A r ...
Two Nb3Sn cable-in-conduit conductors have been procured for Se.C.R.E.T.S. (Segregated Copper Ratio Experiment on Transient Stability), The two conductors are identical in the fractional cross sections. The only difference is the location of the copper sta ...
The European Home Team is responsible for the design, the fabrication and the test of the Toroidal Field Model Coil (TFMC) of the International Thermonuclear Experimental Reactor (ITER), Within this task, three full size samples had to be fabricated by ind ...
An imbalance in the transport current among the strands of a Cable-in-Conduit conductors (CICC) can be associated with the change of their performance. In order to understand and improve the performance of CICC's, it is essential to study the current imbal ...
Transient stability experiments are carried out on a Nb3Sn cable-in-conduit conductor in the SULTAN test facility. A disturbance of variable duration is applied by a pulsed field, transverse to the conductor axis. The results show a high tolerance to large ...
The aim of this work is to determine the existence and degree of the current unbalance of two types of Cable-In-Conduit Conductors (CICC) of the SeCRETS long sample experiment, and its influence on the conductors' performance. The self-field,measurements a ...