A hydrodynamically optimized nano-electrospray ionization source and vacuum interface
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Electron Beam Induced Deposition (EBID) allows deposition of three-dimensional micro- and nano-structures of conductive and insulating materials on a wide range of substrates. The process is based on the decomposition of molecules of a pre-selected precurs ...
We develop a microionizer as the ion source in a miniaturized spectrometerlike gas analyzer, operating at atmospheric pressure. Several options for the ionizing principle were considered. The application of dc glow discharge in a microsystem was studied in ...
Ionization energies (IE) of [M + zH]z+ (z+) electrospray-produced polypeptides were detd. by electron ionization in a Penning cell of 4.7 and 9.4 .T Fourier transform mass spectrometers. For z = 1+ and substance P, the found IE value of 11.0+-0.4 eV is in ...
The derivatization of neutral transition metal carbonyl clusters with an alkoxide anion, [Mn(CO)xOR]- is discussed. The electrospray ionization mass spectrometry technique is used for the purpose. Control of the potential applied to the skimmer cone of the ...
A review, with 9 refs., is given on trace element anal. by mass spectrometry (MS) and potentiometric stripping anal. (PSA). The key question of the problem is detn. of the structure of the samples (i.e. distribution functions and concns. of atoms, mols., c ...
The kinetic energy dependence of ions trapped in a radiofrequency (RF) hexapole ion trap was calcd. as a function of space charge, mean free path, mass, RF potential and charge. The av. kinetic energy of the ions increases with increasing space charge, mea ...
The time-resolved fluxes of negative polysilicon hydride ions from a power-modulated rf silane plasma have been measured by quadrupole mass spectrometry and modeled using a simple polymerization scheme. Experiments were performed with plasma parameters sui ...
Spin-coated solid films of the gold-cluster compd. dodeca-(triphenylphosphine), hexa(chloro)pentapentacontagold Au55(PPh3)12Cl6 are irradiated with a focused 20-keV Ga+ focused-ion beam. Writing speeds on the substrate ranged from 50 up to 2000 mm/s. This ...
We present a new experiment to monitor ionized atom and mass selected cluster depositions in real time using specular reflected thermal helium scattering. Monomer Ag ions with an incident kinetic energy of E/sub dep/=20 eV and E/sub dep/=95 eV create surfa ...