Spatial measurements of the structure of nanometer-sized transmitter vesicles with high-resolution mass spectrometry imaging.
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Nowadays, among the instrumentation park of mass spectrometry, Fourier transform mass spectrometers (FTMS), including ion cyclotron resonance (ICR) and Orbitrap FTMS, provide the highest analytical performance for accurate measurements and mass resolution. ...
Coupling of motion of the ion clouds with close m/z values is a well-established phenomenon for ion-trapping mass analyzers. In Fourier transform ion cyclotron resonance mass spectrometry it is known as ion coalescence. Recently, ion coalescence was demons ...
A gyrokinetic Coulomb collision operator is derived, which is particularly useful to describe the plasma dynamics at the periphery region of magnetic confinement fusion devices. The derived operator is able to describe collisions occurring in distribution ...
Ultraslow radiative cooling lifetimes and adiabatic detachment energies for three astrochemically relevant anions, Cn- (n = 3-5), are measured using the Double ElectroStatic Ion Ring ExpEriment (DESIREE) infrastructure at Stockholm University. DESIREE main ...
A multielectrode ion cyclotron resonance (ICR) cell, herein referred to as the 4X cell, for signal detection at the quadruple frequency multiple was implemented and characterized on a commercial 10 T Fourier transform ICR mass spectrometer (FT-ICR MS). Not ...
Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) has been used to probe the interaction of the anticancer drug cisplatin with oligonucleotides. The binding kinetics, the nature of the adducts formed, and the location of the binding s ...
FLUOLE-2 is a benchmark-type experiment dedicated to 900 and 1450MWe PWR vessels surveillance dosimetry. This two-year program started in 2014 and will end in 2015. It will provide precise experimental data for the validation of the neutron spectrum propag ...
We present here the design of a new tandem mass spectrometer that combines an electrospray ion source with a cryogenically cooled ion trap for spectroscopic studies of cold, gas-phase ions. The ability to generate large ions in the gas phase without fragme ...
In this thesis report, we describe a novel home-built instrument designed to study the spectroscopy of biomolecular ions in the gas phase and at low temperature, and we present the first experimental results obtained on protonated aromatic amino acids. The ...
Combined with high and ultra high pressure liquid chromatography, mass spectrometry-based peptide and protein structure analysis requires high resolution and mass accuracy achievable within short ion detection time. Although Fourier transform ion cyclotron ...