AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The aim of this document is to provide an extended description and application guide of methods belonging to the so-called Numerical Electromagnetic Analysis (NEA) applied to the calculation of electromagnetic transients in power systems. As known, the acc ...
2013
,
The method of symmetrical components is not effective for fault location in the case of untransposed lines, due to potential couplings between the sequence circuits. This paper proposes a non-iterative algorithm in the phase-coordinates for wide-area fault ...
Institute of Electrical and Electronics Engineers2016
The problem of upward leader inception from transmission lines has not been thoroughly discussed, largely because of the difficulty to obtain experimental data under natural circumstances. Previous studies have primarily examined reduced-scale experiments ...
Elsevier2016
A major change in the electrical transmission and distribution system is taking place in Europe at the moment. The shift from a centralised energy production to a distributed generation profoundly changes the behaviour of the grid. Environmental or social ...
EPFL2012
, , ,
The drawbacks of conventional Modular Multilevel Converters (MMC) are described in terms of short-circuits. The configuration of MMC-transformer-MMC proves to handle short-circuits at the input and output without the need for additional DC or AC circuit br ...
For resistive fault current limiters (RFCLs) based on high temperature superconducting coated conductors (HTS-CCs), inhomogeneity, in terms of critical current and geometrical imperfections such as stabilizer and substrate thicknesses, plays a very importa ...
In the operation of power systems, the knowledge of the system state is required by several fundamental functions, such as security assessment, voltage control and stability analysis. By making reference to the static state of the system represented by the ...
The Institution of Engineering and Technology - IET2015
For the simulation of electrical power systems (adjustable speed drives, wind farms, complete grids, etc.) the Kirchhoff's model is used. Each of the components of this model (transmission line, circuit breaker, electrical machines, etc.) is represented by ...
The paper presents a microcontroller-based automatic system that applies the continuous wavelet analysis to the measured fault-originated electromagnetic transients in order to locate phase-to-ground faults in power distribution networks composed by coaxia ...
Current from nearby rocket-triggered lightning that flowed through the soil and into an unenergized test power distribution line was studied based on experimental data acquired in 2003 at the International Center for Lightning Research and Testing in Flori ...