Contribution of the Arterial System and the Heart to Blood Pressure during Normal Aging - A Simulation Study
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
We investigated the patterns of vasomotion in various conduit arteries of the human arm. The internal diameter of the brachial, radial, ulnar, and digital artery was measured noninvasively in 17 healthy volunteers (aged 24-40 yr), using a high-precision ul ...
Isobaric compliance and distensibility of the radial artery were recently reported to be normal or slightly increased in untreated hypertensive patients. However, these findings provide no information on the intrinsic mechanical properties of the wall mate ...
Seven classic and recently proposed methods used for the estimation of total arterial compliance have been evaluated for their accuracy and applicability in different physiological conditions. The pressure and flow data are taken from a computer model that ...
The elastic properties of carotid arteries of spontaneously hypertensive rats (SHR) and normotensive controls (Wistar-Kyoto rats [WKY]) were examined in vivo, in situ, and in vitro. The changes of internal diameter were measured with a high-resolution A-mo ...
In this study we investigated whether there exists a periodic contractile activity of the radial artery, and we evaluated the impact of such an oscillatory behavior on the mechanical properties of this medium-sized muscular vessel. The internal diameter of ...
METHODOLOGY: A new non-invasive ultrasonic device was developed to characterize the biomechanical properties of medium and large peripheral arteries. Simultaneous recordings of internal diameter and blood pressure over the whole cardiac cycle are used to e ...
A computer model for simulating pressure and flow propagation in the human arterial system is developed. The model is based on the one-dimensional flow equations and includes nonlinearities arising from geometry and material properties. Fifty-five arterial ...
We propose a new method to derive aortic pressure from peripheral pressure and velocity by using a time domain approach. Peripheral pressure is separated into its forward and backward components, and these components are then shifted with a delay time, whi ...
We investigated how parameters describing the heart and the arterial system contribute to the systolic and diastolic pressures (Ps and Pd, respectively) and stroke volume (SV). We have described the heart by the varying-elastance model with six parameters ...
To investigate the functional role of different alpha1-adrenergic receptor (alpha1-AR) subtypes in vivo, we have applied a gene targeting approach to create a mouse model lacking the alpha1b-AR (alpha1b-/-). Reverse transcription-PCR and ligand binding stu ...