This paper discusses the findings of an experimental program that was conducted to investigate the behaviour of extended shear tab beam-to-column and beam-to-girder connections that are commonly used in North America. The laboratory results showed that extended beam-to-column shear tab connections could reach resistance levels consistent with typical predicted failure modes and still maintain an adequate level of plastic rotation capacity. The beam-to-girder connection tests revealed that (a) plate local buckling for full-height connections; and (b) localized deformation of the supporting girder web and flange for partial-height connections should be explicitly considered as part of the design process of such connections.
Alain Nussbaumer, Pieter Christian Louter, Jagoda Cupac
Dimitrios Lignos, Ahmed Mohamed Ahmed Elkady
Simon Nessim Henein, Loïc Benoît Tissot-Daguette, Hubert Pierre-Marie Benoît Schneegans, Etienne Frédéric Gabriel Thalmann