AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Total Hip Replacement (THR) is today a routine procedure executed more than 800'000 times per year worldwide. THR gives generally satisfactory results, although the quality of outcome is inversely proportional to the age of the patient. In parallel, there ...
Motivated by applications in orthopaedic surgery, new constitutive laws for trabecular (or spongious) bone are developed in the framework of continuum mechanics, implemented in a mechanical analysis computer program, validated by a number of in vitro exper ...
In order to decrease the peri-implant bone loss during the life-time of the implant, oral use of anti-osteoporosis drugs (like bisphosphonates) has been suggested. In this study, bone remodeling parameters identified from clinical trials of alendronate wer ...
A force-sensing device to intraoperatively measure knee joint forces and moments to improve the ligament balancing procedure during total knee arthroplasty has been developed. It consists of two sensitive plates, one for each condyle, a tibial base plate a ...
There is strong evidence to suggest that inducible displacements, migration and implant loosening are closely related to the initial mechanical environment of the implanted tibia. If this is true, then it should be possible to predict the likelihood of imp ...
Orthopedic implant failures are often associated with peri-implant osteolysis. Particles generated from the wear process have been suspected to play an important role in this situation. Indeed, the peri-implant osteolysis could be due to the presence of pa ...
A model of tissue differentiation at the bone-implant interface is proposed. The basic hypothesis of the model is that the mechanical environment determines the tissue differentiation. The stimulus chosen is related to the bone-implant micromotions. Equati ...
A micro system for measuring the relative displacements between a bone and an implant in a prosthetic hip of a human being has been realized. Novel are the small dimensions of the system combined with the possibility to measure relative displacements in th ...
Particles generated from orthopedic implants through years of wear play an essential role in the aseptic loosening of a prosthesis. We have investigated the biocompatibility of these orthopedic particles on different osteoblast-like cells representative of ...