We consider the problem of super-resolution from unregistered aliased images with unknown spatial scaling factors and shifts. Due to the limitation of pixel size in the image sensor, the sampling rate for each image is lower than the Nyquist rate of the sc ...
In this thesis the concept, modelling, design, fabrication process and characterization of novel optical modulators are presented. The devices consist of flaps exhibiting a large tilt with electrostatic actuation at low voltages. The applications comprise, ...
X-ray computed tomography (XRCT) can reconstruct, in a nondestructive way and in three-dimension, the distribution of densities within opaque materials. Consequently, it provides an effective possibility to characterize the inner content of rock core sampl ...
Optical coherence tomography (OCT) is an interferometric imaging technique that can provide depth resolved cross-sectional views of biological tissue. OCT employs light with low temporal and yet high spatial coherence. The sample is illuminated point by po ...
In this paper, a digital pixel sensor in silicon on insulator (SOI) is presented. The active part is a partially depleted SOI phototransistor. The technique elaborated in Harik et al. (2008) [1] was designed and implemented. Moreover, we took advantage of ...
Phase-sensitive X-ray imaging methods can provide substantially increased contrast over conventional absorption-based imaging, and therefore new and otherwise inaccessible information. Differential phase-contrast (DPC) imaging, which uses a grating interfe ...
Abstract-In this paper, a digital pixel sensor in SOl is presented. The active part is a partially depleted Sol phototransistor. The technique elaborated in [I] was designed and implemented. Moreover, we took advantage of some of the characteristics of the ...
IEEE Service Center, 445 Hoes Lane, Po Box 1331, Piscataway, Nj 08855-1331 Usa2009
The present invention relates to an interferometer for x-rays, in particular hard x-rays, for obtaining quantitative x-ray images from an object, comprising: a) an x-ray source, preferably a standard polychromatic x-ray source, b) a diffractive beam splitt ...
The present thesis develops some specific aspects of digital holographic microscopy (DHM), namely the effect of shot noise on the phase image accuracy, the use of DHM in micro-tomography and in aberrations evaluation of a microscope objective (MO). DHM is ...
This thesis presents a new tomographic imaging method using multiple wavelengths in digital holographic microscopy. It is based on the addition of several reconstructed wavefronts measured at different wavelengths. The resulting diffraction tomographic vis ...
EPFL2006
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.