Profile control simulations and experiments on TCV: a controller test environment and results using a model-based predictive controller
Publications associées (69)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
A high-order, multivariable, modern plasma controller has been designed using H-infinity optimal control techniques and tested oil the Tokamak Configuration Variable (TCV) tokamak. An initial design for the control of the plasma current, position, and shap ...
The effects of thermal trapped particles on the n = 1 internal kink mode are studied using drift kinetic theory. Strong modifications of the magnetohydrodynamic (MHD) results are found, and marginal stability generally occurs at nonzero rotation frequency. ...
A fully kinetic assessment of the stability properties of toroidal drift modes has been obtained for nonaxisymmetric (stellarator) geometry, in the electrostatic limit. This calculation is a comprehensive solution of the linearized gyrokinetic equation, us ...
Stability limits for the ideal internal kink mode are calculated analytically for the Shafranov current profile using the large aspect ratio expansion. For equilibria with q(a) > 2 and circular cross-section, the maximum stable poloidal beta is below 0.1. ...
There is not yet a straightforward method for determining the D-T ratio in the centre of a tokamak plasma. One of the simpler measurements put forward in the past is the interpretation of the MHD spectrum in the frequency range of the global Alfven eigenmo ...
A new vertical position control system, including an internal active coil, has become operational on TCV. The new system has made it possible to stabilize plasmas with open loop growth rates up to 4400 s(-1), currents up to 1.0 MA and elongations up to 2.5 ...
Kinetic effects such as finite ion Larmor excursions and resonant Landau interactions are studied in the toroidicity Alfven eigenmode (TAE) range of frequencies. A new Alfven mode conversion mechanism is described taking place away from the resonances thro ...
Growth rates of the axisymmetric mode in vertically elongated plasmas in the Tokamak a Configuration Variable (TCV) are measured and compared with numerically calculated growth rates for the reconstructed equilibria. This comparison is made over a range of ...