An adaptive structure for sigma delta modulation with improved dynamic range
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Radio interferometry probes astrophysical signals through incomplete and noisy Fourier measurements. The optimal reconstruction of these signals is an important topic not only for current astronomical imaging but also that of the next generation of radio t ...
Ca2+-evoked transmitter release shows a high dynamic range over spontaneous release. We investigated the role of the Ca2+ sensor protein, Synaptotagmin2 (Syt2), in both spontaneous and Ca2+-evoked release under direct control of presynaptic Ca2+, usin ...
Vision sensors whose pixels asynchronously generate informative output events are gathering increasing interest because they can reduce the data latency, rate, and redundancy, while also increasing dynamic range. This paper proposes such a dynamic vision s ...
In this paper we describe and implement a long-range Brillouin optical time-domain analysis (BOTDA) sensor, for both temperature and strain measurements, using optical pulse coding techniques. A theoretical analysis of Simplex coding applied to BOTDA syste ...
We have used distributed Raman amplification to extend the measurement distance of a Brillouin Optical Time-Domain Analysis (BOTDA) sensor. We successfully demonstrate a dynamic range of 75 km with 2 meter spatial resolution. ...
We have used distributed Raman amplification to extend the measurement distance of a Brillouin Optical Time-Domain Analysis (BOTDA) sensor. We successfully demonstrate a dynamic range of 75 km with 2 meter spatial resolution. ...
The International Society for Optical Engineering2010
We present a linear multicast of an analog signal in a two-pump self-seeded parametric device. The linearity of the parametric multicasting is assessed by two-tone measurements of the third-order intermodulation products and radio-frequency spectral analys ...
Institute of Electrical and Electronics Engineers2010
This paper is concerned with input adaptation in dynamic processes in order to guarantee feasible and optimal operation despite the presence of uncertainty. For optimal control problems having terminal constraints, two sets of directions can be distinguish ...
A switched-capacitor logarithmic pipeline analog-to-digital converter (ADC) that does not require squaring or any other complex analog function is presented. This approach is attractive where a high dynamic range (DR), but not a high peak SNDR, is required ...
Autofluorescence (AF) from bronchial tissue is increasingly used for the endoscopic detection of early bronchial neoplasia. Several imaging systems are commercially available, all detecting the absolute or relative AF intensity and/or spectral contrasts be ...