A Full-Scale Experimental Validation of Electromagnetic Time Reversal Applied to Locate Disturbances in Overhead Power Distribution Lines
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Factors that contribute to lightning-caused faults on the line insulation of overhead distribution lines and suggested improvements to existing and new constructions are identified in this guide. ...
The paper describes the performances of a phasor measurement unit (PMU) prototype based on a synchrophasor estimation algorithm conceived for the monitoring of active distribution networks, as well as its experimental application during some intentional is ...
The aim of the paper is to analyze overvoltages in overhead distribution lines induced by nearby lightning return stroke currents taking into account also the conductive coupling between the lightning current injected into the soil and the line's grounding ...
This design guide contains information on methods to improve the lightning protection performance of overhead distribution lines and is written for the distribution-line designer. This guide recognizes that a perfect line design does not exist and that a s ...
The paper presents the main characteristics of a centralized two-stage scheduler designed for the integration in the Distribution Management System (DMS) under development in the framework of an Italian "Smart Grid" Project. The paper first reviews the tre ...
Two identical conductor samples were fabricated from 110 m length cable prepared for qualification of the manufacturing process for Phase II procurement of ITER TF conductor. Superconducting strand characteristics, cabling specifications, and the stainless ...
The computation of lightning-originated surges on overhead power lines due to nearby lightning return strokes requires accurate models for the calculation of both the incident lightning electromagnetic pulse (LEMP) and the coupling of this field with the l ...
This thesis analyses and models the vulnerability of the electricity power supply under extreme weather conditions. The system under study is the electric supply system that includes major power plants to main load centers. Extreme weather conditions can c ...
This paper deals with the calculation of lightning-induced overvoltages on medium-voltage (MV) and low-voltage (LV) distribution networks taking into account the presence of MV-LV distribution transformers and, in particular, the surge transfer through the ...
The evaluation of electromagnetic transients in overhead power lines due to nearby lightning return strokes requires accurate models for the calculation of both the incident lightning electromagnetic pulse ( LEMP) and the effects of coupling of this field ...