A Modified Formula for Distance Relaying of Tapped Transmission Lines with Grounded Neutrals
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Current from nearby rocket-triggered lightning that flowed through the soil and into an unenergized test power distribution line was studied based on experimental data acquired in 2003 at the International Center for Lightning Research and Testing in Flori ...
The DC performances of three full- and five sub-size NbTi cable-in-conduit conductors, measured in the SULTAN test facility, are compared. In general, the self-field effect was found to cause sudden take-offs at high currents. In most of the investigated c ...
In this paper, we first extend the Sunde logarithmic approximation for the single-wire line ground impedance to the case of a multiconductor line. The new approximate forms are compared to the general expressions which involve integrals over an infinitely ...
Lightning-induced voltages in power and communication systems are nowadays one of the main causes of power quality and electromagnetic compatibility. In recent years, due to the increasing demand by customers for good quality in the power supply along with ...
The present paper deals with a new approach for the study of the steady-state and transient behaviour of phase transformers. This approach based on magnetic equivalent circuit diagrams, takes into account the nonlinear B-H curves as well as zero-sequence f ...
This paper deals with a combined analytical-numerical approach for the study of the steady-state and transient behaviour of three-phase transformers. This approach based on magnetic equivalent circuits, takes into account the nonlinear B-H curve. The nonli ...
This paper deals with the calculation of lightning-induced overvoltages on medium-voltage (MV) and low-voltage (LV) distribution networks taking into account the presence of MV-LV distribution transformers and, in particular, the surge transfer through the ...
Six-phase a.c. motor drives are usually supplied from two-level six-phase voltage source inverters (VSIs), which are controlled using appropriate PWM techniques. Most of the existing work applies to the asymmetrical six-phase VSI, supplying an asymmetrical ...
While most of the emphasis has been focused on the radiated threat represented by intentional electromagnetic interference, it is clear that the threat from conducted disturbances should not be neglected. Conducted threats include those that are produced b ...
The appraisal of the response of distribution networks to the excitation of lightning electro magnetic pulse (LEMP) requires the availability of accurate models of LEMP-illuminated lines. These models should be able to take into account the presence of shi ...