Patellar bone strain after total knee arthroplasty is correlated with bone mineral density and body mass index
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Mobile-bearing total knee arthroplasty has potential advantages over fixed- bearing prostheses that may lead to an improvement of the range of motion and inferior long-term polyethylene wear. However, the potential disadvantages include the dislocation of ...
In orthopaedics, outcome evaluation is currently recognized as a major challenge to improve the knowledge both about injuries and treatments. For anterior cruciate ligament (ACL) rupture, various evaluation tools are available for routine uses: clinical ex ...
Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee jo ...
Total joint replacements are highly successful in relieving pain and restoring movement of damaged joints. However, the lifespan of the implants is limited. The implant's long-term stability depends largely on the preservation of periprosthetic bone. Debri ...
Joint simulators are widely used to perform pre-(and post) clinical test of joint prostheses. Several experimental or commercial devices already exist for the hip and knee joints, but nothing is available yet for the shoulder joint. The first goal of this ...
Nowadays, the large majority of the instrumentation for orthopaedic surgery consists of mechanical tools with varying degrees of complexity. To increase the accuracy and the safety of orthopaedic interventions, sensors and computers were recently introduce ...
The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function ...
Probe (1) used during a total knee arthroplasty for measuring forces and locations of their points of application and thereby moments comprising A) two load sensitive plates (2 3) apt to be inserted in one joint-compartment of a knee joint each and each be ...
Background. Previous experimental studies have been conducted to evaluate the biomechanical effects of posterior cruciate ligament reconstruction; but no consensus has been reached on the preferred method of reconstruction. Methods. The 3D finite element m ...
A force-sensing device to intraoperatively measure knee joint forces and moments to improve the ligament balancing procedure during total knee arthroplasty has been developed. It consists of two sensitive plates, one for each condyle, a tibial base plate a ...