AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
In this report different air-water heat pump cycles under the operating conditions of the retrofit market and in the low heating power range are examined. The already existing heat pump models show excessive power and efficiency loss at very low ambient te ...
Targeting the integration of the utility system in an industrial site, introduces the problem of combined heat and power production and more specifically the optimal integration of the steam network. We present a mathemat ical tool that allows, using only ...
Air conditioning unit for vehicle which is compact and economical, while ensuring simplification of the combination of means for controlling the temperature of different elements of the vehicle. The unit comprises a fan which supplies two conduits placed p ...
A brine/water heat pump with the auxiliary liquid subcooling cycle with a heating capacity of 9 kW at -7/50°C was built and a series of measurement were conduced. The heat pump is designed for the monovalent heating in the retrofit market. For this purpose ...
Replacing conventional boilers by air to water heat pumps represents a major market opportunity and a contribution to more sustainable heating approaches. However, such retrofit situation impose tough technical requirements which must be met in order to de ...
Intube evaporation tests for R-407C and R-407C/oil are reported for a plain copper tube. The tests were run at a nominal inlet pressure of 6.45 bar (93.5 psia) at mass velocities of 100, 200 and 300 kg/m2s (73581, 147162 and 220743 lb/h ft2) over nearly th ...
The capacities of performance improvements of low and mid-size heat pumps are studied in this project. For the new buildings market, the components of the heat pump match already well the requirements for high performance and monovalent heating. Minor impr ...
A complex heating and cogeneration plant including two 3.9 MWth ammonia heat pumps and two 3 MWel gas turbines with heat recovery boilers and three storage tanks of 66 GJ has been in operation since 1986. The heating surface is actually about 280’000 m2 an ...
A complex heating and cogeneration plant including two 3.9 MWth ammonia heat pumps and two 3 MWel gas turbines with heat recovery boilers and three strage tanks has been in operation since 1986. This paper is a result of an expreimental evaluation during t ...
The objectives of the present work is to theoretically and experimentally demonstrate the advantages of a two-stage cycle equipped with an economizer and single variable speed compressor for heat pumps using air as cold source. Furthermore, an efficient de ...