Êtes-vous un étudiant de l'EPFL à la recherche d'un projet de semestre?
Travaillez avec nous sur des projets en science des données et en visualisation, et déployez votre projet sous forme d'application sur Graph Search.
This paper presents the results of a series of shake table tests carried out on a half-scale single-story unreinforced masonry building with asymmetric openings. First, the unretrofitted building is subjected to seven increasing steps of bidirectional seismic excitation. The damaged building is then rehabilitated using steel mesh and shotcrete layer with two walls retrofitted from the exterior face and the other two from the interior face. Afterward, the shake table test is again conducted on the retrofitted specimen in nine increasing excitation levels. Three cases of interior-to-interior, interior-to-exterior, and exterior-to-exterior shotcrete connections are considered at the intersection of perpendicular walls, and for each case, the development of cracks is investigated. Moreover, the effects of fixity of the shotcrete vertical rebars in the foundation are investigated through releasing the rebar-foundation connection in the last three steps of the test on the rehabilitated specimen. The results indicate the adequacy of the retrofit method in creating a strong bond that leads to an acceptable composite action between the brick layer and shotcrete; though, concentrated cracks were observed at the connections of the perpendicular walls. Furthermore, the shotcrete layer has proven to be able to prevent further propagation of the previously developed cracks, which can provide a practical solution for rehabilitation of damaged masonry buildings.
, ,
Katrin Beyer, Qianqing Wang, Ketson Roberto Maximiano Dos Santos