Modeling of the response function of CdTe detectors for a hard X-ray synthetic diagnostic
Publications associées (37)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
A pulse height analysis (PHA) x-ray system has been successfully implemented on the tokamak TCV, aiming at a low cost monitor system of the plasma electron temperature and impurity content. To meet the need for high throughput and fast acquisition, mandato ...
A large CdTe-based tomographic system has been installed two years ago on the TORE SUPRA tokamak, for a detailed investigation of the dynamics of fast electrons generated by radio-frequency waves in Fusion plasmas, as a function of time, space and energy. ...
This paper shows the importance and feasibility of real-time tomography in fusion experiments for the example of soft X-ray (SXR) position measurements. The requirement of non-magnetic real-time diagnostics in low frequencies for ITER is discussed. This is ...
The design and first results are presented from a bolometric diagnostic with high temporal resolution recently installed on the TCV tokamak. The system consists of two pinhole cameras viewing the plasma from above and below at the same toroidal location. E ...
The dynamical response of a soft X ray emission profile to different external perturbations - gas feed, impurity injection, RF power, surface loop voltage - has been studied on the TCA tokamak and analysed using a single technique. The frequency dependence ...
A method of obtaining a relative calibration of Si photodiodes for the spectral range of soft x rays (1-30 KeV) is presented. A simple mathematical model of the p-n diode is adopted which allows the response to be described in terms of a small set of param ...
We report three RXTE/PCA observations of the low-mass X-ray binary 4U 0614+09. They show strong (similar to 30% rms) band-limited noise with a cutoff frequency varying between 0.7 and 15 Hz in correlation with the X-ray flux, f(x). We observe two nonsimult ...