Seismic testing of adjacent interacting masonry structures
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Filling materials may exist in all scales of rock fractures, not only influencing seismic wave attenuation, but controlling rock mass instability. The objective of this study is to experimentally investigate the seismic response of rock fractures filled wi ...
For a shake table test on a four-storey structure with both unreinforced hollow-core brick masonry (URM) walls and reinforced concrete (RC) walls, the test unit had to be constructed at half-scale. While past experience showed that testing RC structural el ...
Modern unreinforced masonry buildings with reinforced concrete slabs are often retrofitted by inserting reinforced concrete walls. The main advantages of this technique are the increase in strength and displacement capacity with respect to masonry structur ...
When testing multi-storey structures, most testing facilities require the testing of a reduced-scale model. A literature review on tests of scaled masonry structural components revealed that scaling of masonry was rather challenging and often significant d ...
With the introduction of higher seismic design forces in the Swiss loading standard of 2003 most unreinforced masonry (URM) buildings failed to satisfy the seismic design check. For this reason, in new construction projects, a number of URM walls are nowad ...
Unreinforced masonry (URM) structures are known to be rather vulnerable to seismic loading. Modern URM buildings with reinforced concrete (RC) slabs might, however, have an acceptable seismic performance for regions of low to moderate seismicity. In partic ...
In Switzerland many new residential buildings are constructed as unreinforced masonry (URM) structures or as mixed structures where URM walls are coupled with reinforced concrete (RC) walls by RC slabs. At present the boundary conditions of URM walls subje ...
In several countries of moderated seismicity, with the re-evaluation of the seismic hazard most unreinforced masonry (URM) buildings with reinforced concrete slabs failed to satisfy the seismic design check. A possible seismically retrofit solution consist ...
As an approach to the problem of seismic vulnerability evaluation of existing buildings using the predicted vulnerability method, numerical models can be applied to define fragility curves of typical buildings which represent building classes. These curves ...
The seismic assessment of existing buildings has been underestimated in regions with moderate seismic hazard, such as the North-West Europe. Strong earthquakes, such as the 1356 Basel earthquake, already occurred in such regions and caused severe damage. T ...