AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Most codes of practice adopt a semi probabilistic design approach for the dimensioning and assessment of structures. Accordingly, structural safety is ensured by performing limit state verifications using design values determined with adequately calibrated ...
In the evolution of structural glass beam elements, the requirements for post-fracture load bearing capacity and safe failure behaviour have led to the development of reinforced and post-tensioned beams. Maximum bending capacity in the post-fracture state ...
The forms of U-shaped UHPFRC beams have not been investigated for the highway footbridge. Compared with the traditional section forms, the U-shaped UHPFRC beams can reduce the material consumption under the condition of providing the same bearing capacity. ...
The reduction of green-house gas emissions is one of the global challenges that our society is facing and the production of cement plays a major role because concrete is the most used material worldwide. For every 1000 kg of cement produced, 900 kg of CO2, ...
Traditionally, the concrete strength is measured on cubes or cylinders having normalized dimensions, suitable vibration and curing conditions and their strength is assessed in laboratory under fast loading rates. However, the in-situ strength of structural ...
The significance of sustained loading on the compressive and tensile strength of concrete has been experimentally verified since the 1950s and is currently acknowledged in most design codes implicitly or explicitly. However; its influence on other potentia ...
Sustained load actions are permanently present in concrete structures, as for example self-weight and dead loads on bridges or soil pressure on cut-and-cover tunnels. These actions may increase throughout a structure's lifetime, for instance after refurbis ...
EPFL2019
, ,
Correct detailing and positioning of lap splices is essential in order to prevent premature failure of reinforced concrete structural members. Especially before the introduction of capacity design guidelines, lap splices were often placed in member regions ...
SPRINGER2019
, , ,
The use of punching shear reinforcement is currently considered as one of the most convenient practices to enhance the punching shear strength and deformation capacity of slab-column connections in flat slabs. Intensive research has been performed in the l ...
Fédération Internationale du Béton (fib)2021
,
Despite edge columns being instrumental components of flat slabs, most punching research has focused on internal connections. Several particularities of edge columns, such as load eccentricity and moment transfer, require additional experimental investigat ...