Lightning-Induced Voltage on an Overhead Transmission Line Terminated with Non-veritical Risers
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The aim of this document is to provide an extended description and application guide of methods belonging to the so-called Numerical Electromagnetic Analysis (NEA) applied to the calculation of electromagnetic transients in power systems. As known, the acc ...
For the case of urban overhead lines, the presence of nearby buildings is expected to affect the overvoltages induced by nearby cloud-to-ground lightning return strokes. So far, this effect has been seldom taken into account in the literature on the subjec ...
We discuss the transmission line (TL) theory and its application to the problem of lightning electromagnetic field coupling to TLs. We start with the derivation of the general field-to-TL coupling equations for the case of a single-wire line above a perfec ...
For the case of urban overhead lines, the presence of nearby buildings is expected to affect the overvoltages induced by nearby lightning return strokes. This effect until now has been seldom taken into account in the literature on the subject. The paper p ...
The aim of the paper is to analyze overvoltages in overhead distribution lines induced by nearby lightning return stroke currents taking into account also the conductive coupling between the lightning current injected into the soil and the line's grounding ...
The evaluation of electromagnetic transients in overhead power lines due to nearby lightning return strokes requires accurate models for the calculation of both the incident lightning electromagnetic pulse ( LEMP) and the effects of coupling of this field ...
Measurement units of high-frequency voltage transients have been specifically developed and installed at three different busses of an Italian medium voltage (MV) feeder, mainly composed by overhead lines and located in a rural region characterized by a hig ...
The effect of structure height on the lightning striking distance is estimated using a lightning strike model that takes into account the effect of connecting leaders. According to the results, the lightning striking distance may differ significantly from ...
Monitoring units for the measurement of high frequencyvoltage transients have been in operation at three different busses of an Italian medium voltage (MV) distribution feeder, mainly composed by overhead lines, in March 2007 – August 2008. The feeder is l ...
The paper deals with the evaluation of the indirect-lightning performance of overhead distribution networks. The novelty of this contribution is that it takes into account the inherent complexity of distribution networks. These networks are indeed characte ...