Seismic response of historical masonry buildings and aggregates - large-scale experimental testing and macro-element modelling
Publications associées (106)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
«For me, to build an air terminal with stone would be a stupidity, not to say a madness. But to use dynamic structures to fit three-roomed flats with kitchen in buildings from three to ten floors, is not less aberrant.»1 Provocation of a reactionary archit ...
Fragility functions that permit the estimation of damage in pre-1994 welded flange bolted-web beam-to-column moment connections are developed. The fragility functions provide estimates of the probability of yielding and of experiencing fracture as a functi ...
Seismic verification of existing buildings in Switzerland is currently assessed by the pre-standard 2018. In the seismic evaluation of existing buildings in that document, a minimal acceptable seismic safety must be verified, as well as proportional level ...
In many unreinforced masonry (URM) buildings reinforced concrete (RC) ring beams are introduced at each storey in order to maintain the integrity of the building when subjected to seismic loading. Such ring beams also contribute to the in-plane resistance ...
Most residential buildings that were constructed during the last century in Switzerland are 2-6 storey unreinforced masonry (URM) structures. At the beginning of the century, houses were constructed with timber floors and small bricks. This type of constru ...
Experimental results gained from quasi-static cyclic tests on 34 slender structural reinforced concrete walls available in the literature are used to examine the shear deformations for displacement demands in the inelastic range. Based on these results the ...
The seismic assessment of existing buildings has been underestimated in regions with moderate seismic hazard, such as the North-West Europe. Strong earthquakes, such as the 1356 Basel earthquake, already occurred in such regions and caused severe damage. T ...
Seismic risk in regions with moderate seismicity, such as Switzerland, was largely underestimated. A vast majority of existing buildings have been built without specific earthquake resistant features and do not meet modern requirements. Although several pr ...
The aim of this paper is to adjust behaviour models for each class of structure for vulnerability assessment by using ambient vibration. A simple model based on frequencies, mode shapes and damping, taken from ambient vibrations, allows computation of the ...