Multiple scattering in wide-field optical coherence tomography

Boris Clément Karamata
2004
Thèse EPFL
Résumé

Optical Coherence Tomography (OCT), a well-established imaging method based on low-coherence interferometry, provides cross-sectional images of the internal structure of biological samples with a resolution in the micrometer range. OCT was successfully applied on various tissues such as for instance the retina, the skin or a tooth. In highly scattering tissues like the skin, probing depth is limited to approximately 2mm, mainly due to insufficient rejection of multiply scattered light. Presently, the contribution of multiple scattering in OCT is not fully understood. Therefore, there is a strong and urgent need to develop models allowing a reliable evaluation of the system's limitations as well as the improvement of the imaging capabilities. It is generally believed that a relevant model should account for loss of correlation between the reference and the sample field due to multiple scattering. We developed a new comprehensive model of OCT. Our preliminary study revealed that the reference and sample fields are actually fully correlated. This important result allowed us to model the OCT signal as a sum of stationary random phasors and treated it as a statistical signal. The mean of this signal can be calculated thanks to classical results of statistical optics and to a Monte Carlo simulation. Unlike other existing models, our model accounts for the source autocorrelation function. The model proved to be in excellent agreement with a whole range of experimental data gathered in a comprehensive study of cross-talk in wide-field OCT. Moreover, our results put in question the applicability of widely used models of OCT based on the "extended Huygens-Fresnel principle", which assume a partial correlation between interfering fields due to multiple scattering. The construction of conventional OCT images is based on lateral scanning of a beam focused within the sample. To increase image acquisition speed and eliminate the need for lateral scanning, wide-field OCT was recently developed. Our experimental and theoretical investigations of the potential and limitations of wide-field OCT revealed the crucial role played by the spatial coherence of the light source. Spatially coherent illumination generates considerable coherent optical cross-talk, which prevents shot-noise-limited detection and diffraction-limited imaging in scattering samples. The dependence on several parameters of the optical system and of the sample properties was investigated in a comprehensive study. Cross-talk increases with the wide-field diameter, numerical aperture, source coherence length, and sample optical density; and strongly depends on sample anisotropy. We showed that spatially incoherent illumination realized with a thermal light source permits cross-talk suppression in wide-field OCT, i.e. rejection of multiply scattered light to a level comparable to that of point scanning OCT. We performed a theoretical study which revealed that the power per spatial mode radiated by thermal light sources is too low to permit a high signal-to-noise ratio while maintaining a fast acquisition speed. Therefore, wide-field OCT realized with either spatially coherent or spatially incoherent illumination suffers from inherent fundamental limitation. This led us to investigate the possibility of exploiting a spatially incoherent light source brighter than a thermal light source. We came to the conclusion that such a "pseudothermal" light source can potentially lead to wide-field OCT systems devoid of cross-talk and an image acquisition speed higher than that of a point scanning OCT system. However, the attractive properties of pseudothermal light sources could be gained at the expense of the simplicity and the economical advantages offered by thermal light sources. Furthermore, fast acquisition speed also relies on a performing "smart pixel detector array". Presently, such detectors do not have sufficient sensitivity and their frequency readout is too low as shown in our feasibility study. We performed a theoretical investigation of the potential of thermal light sources in terms of axial resolution and power per mode. The former revealed that the maximum power per mode is radiated at a wavelength higher than the spectral peak of a blackbody radiator. This led to the important practical conclusion that, at 6000 K, the maximum power is collected in the therapeutic spectral window in OCT (600 - 1300 nm), while at 3000 K this peak is shifted out of the therapeutic window leading to significant power losses. More generally, our work provides a design tool for choosing the optimal thermal light source for a given therapeutic window in terms of signal-to-noise ratio. Currently available sources at 6000 K consist of high pressure gas arc lamps providing a spectrum endowed with spectral lines deleterious for OCT. By suppressing a portion of the spectrum devoid of spectral lines of a mercury arc lamp, we obtained amongst the highest axial resolution so far reported in OCT. Furthermore, the importance of the speckle statistics in OCT incited us to clarify the origin of a difference between two theoretical results reported in the literature. Indeed, two calculations of the amplitude distribution of speckles in OCT, each of them based on a different mathematical formulation, yield different results. We showed that a modification of an initial assumption in one of the formulation leads to equivalent results. In conclusion, this thesis provides a deeper understanding of the potential and limitations of widefield OCT, leading to important design rules. Moreover, it presents a new comprehensive model of OCT putting in question other widely used models.

À propos de ce résultat
Cette page est générée automatiquement et peut contenir des informations qui ne sont pas correctes, complètes, à jour ou pertinentes par rapport à votre recherche. Il en va de même pour toutes les autres pages de ce site. Veillez à vérifier les informations auprès des sources officielles de l'EPFL.
Concepts associés (40)
Tomographie en cohérence optique
vignette|Image OCT d'un sarcome La tomographie en cohérence optique ou tomographie optique cohérente (TCO ou OCT) est une technique d' bien établie qui utilise une onde lumineuse pour capturer des images tridimensionnelles d'un matériau qui diffuse la lumière (par exemple un tissu biologique), avec une résolution de l'ordre du micromètre (1 μm). La tomographie en cohérence optique est basée sur une technique interférométrique à faible cohérence, utilisant habituellement une lumière dans l'infrarouge proche.
Cohérence (physique)
La cohérence en physique est l'ensemble des propriétés de corrélation d'un système ondulatoire. Son sens initial était la mesure de la capacité d'onde(s) à donner naissances à des interférences — du fait de l'existence d'une relation de phase définie — mais il s'est élargi. On peut parler de cohérence entre 2 ondes, entre les valeurs d'une même onde à deux instants différents (cohérence temporelle) ou entre les valeurs d'une même onde à deux endroits différents (cohérence spatiale).
Interférométrie
vignette|Le trajet de la lumière à travers un interféromètre de Michelson. Les deux rayons lumineux avec une source commune se combinent au miroir semi-argenté pour atteindre le détecteur. Ils peuvent interférer de manière constructive (renforcement de l'intensité) si leurs ondes lumineuses arrivent en phase, ou interférer de manière destructive (affaiblissement de l'intensité) s'ils arrivent en déphasage, en fonction des distances exactes entre les trois miroirs.
Afficher plus
Publications associées (105)

3D diffractive optics for linear interconnects and nonlinear processing

Niyazi Ulas Dinç

The optical domain presents potential avenues for enhancing both computing and communication due to its inherentproperties of bandwidth, parallelism, and energy efficiency. This research focuses on harnessing 3-Dimensional (3D)diffractive optics for novel ...
EPFL2024

High sensitivity, incoherent differential imaging

Chiara Bonati

Microscopic visualisation of optically transparent samples has been a topic of interest for several decades. Features such as density or chemical composition can influence the optical phase of transmitted light, and phase contrast can reveal these structur ...
EPFL2022

Optical Diffraction Tomography Using Nearly In-Line Holography with a Broadband LED Source

Demetri Psaltis, Abhijit Roy, Ahmed Ayoub

We present optical tomography methods for a 3D refractive index reconstruction of weakly scattering objects using LED light sources. We are able to record holograms by minimizing the optical path difference between the signal and reference beams while sepa ...
MDPI2022
Afficher plus
MOOCs associés (18)
Digital Signal Processing [retired]
The course provides a comprehensive overview of digital signal processing theory, covering discrete time, Fourier analysis, filter design, sampling, interpolation and quantization; it also includes a
Digital Signal Processing
Digital Signal Processing is the branch of engineering that, in the space of just a few decades, has enabled unprecedented levels of interpersonal communication and of on-demand entertainment. By rewo
Digital Signal Processing I
Basic signal processing concepts, Fourier analysis and filters. This module can be used as a starting point or a basic refresher in elementary DSP
Afficher plus

Graph Chatbot

Chattez avec Graph Search

Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.

AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.