Optimization of a Heating, Cooling and Power Generation District Unit based on a Solid Oxide Fuel Cell - Gas Turbine Combined Cycle from the Viewpoints of Cost and CO2 Emissions
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
A more widespread usage of heat pumps would contribute to significantly reduce both local and global environmental impacts. This is particularly relevant within cities, where advanced integrated energy systems incorporating heat pumps and associated with d ...
For the most part, district heating demands can be met by an appropriate intergration of cogeneration and heat pumps units provided that advantages is taken of the fact that many urban regions are concentrated around surface waters. Despite the fact that t ...
A new type of air-water heat pump has been developed with the aim to cover an extended application range in high temperature residential heating (for retrofitting existing oil or gas boilers in hydronic heating systems). The base heat output is about 10 kW ...
A brine/water heat pump with the auxiliary liquid subcooling cycle with a heating capacity of 9 kW at -7/50°C was built and a series of measurement were conduced. The heat pump is designed for the monovalent heating in the retrofit market. For this purpose ...
A design methodology allowing engineers to consider simultaneously and from the earliest phases of design some of the key factors of sustainable development (pollution, life cycle data) has been developed and successfully demonstrated on two examples of in ...
The paper describes two 3.9 MWth ammonia heat pumps of a District Heating plant which also includes two gas turbine cogeneration units. After nine years of reliable operation the heat pumps still show excellent coefficients of performance of above 4.1. Thi ...
For the most part, district heating demands can be met by an appropriate integration of cogeneration and heat pumps units provided that advantage is taken of the fact that many urban regions are concentrated around surface waters. Such an integration resul ...