MicrofluidiqueLa microfluidique est la science et la technique des systèmes manipulant des fluides et dont au moins l'une des dimensions caractéristiques est de l'ordre du micromètre. George Whitesides définit la microfluidique comme « la science et la technologie des systèmes qui manipulent de petits volumes de fluides ( à ), en utilisant des canaux de la dimension de quelques dizaines de micromètres ». Selon Patrick Tabeling, Tabeling précise qu'il entend essentiellement par « nouvelles techniques » la microfabrication héritée de la micro-électronique.
Droplet-based microfluidicsDroplet-based microfluidics manipulate discrete volumes of fluids in immiscible phases with low Reynolds number and laminar flow regimes. Interest in droplet-based microfluidics systems has been growing substantially in past decades. Microdroplets offer the feasibility of handling miniature volumes (μl to fl) of fluids conveniently, provide better mixing, encapsulation, sorting, sensing and are suitable for high throughput experiments.
Pince optiqueLa pince optique est un outil optique introduit en 1987 et utilisé en laboratoire qui permet le piégeage et la manipulation de cibles telles que les cellules, organites ou particules. Elle utilise la force résultant de la réfraction d’un faisceau laser en milieu transparent, pour maintenir et déplacer physiquement des objets diélectriques microscopiques. Des pinces optiques multiples peuvent même être utilisées pour manipuler simultanément plusieurs cibles.
Laboratoire sur puceUn laboratoire sur puce est un dispositif intégré rassemblant, sur un substrat miniaturisé, une ou plusieurs fonctions de laboratoire. L'analyse du vivant regroupe trois des quatre raisons majeures ayant entraîné le développement de la microfluidique ; elle représente par conséquent une large part des applications. On considère généralement que le premier dispositif microfluidique d'analyse est celui développé par Terry et al. ; ceux-ci réalisent en 1979 un système miniaturisé d'analyse de gaz par chromatographie sur un substrat de silicium.
Piège magnéto-optique350px|thumb|Montage expérimental d'un piège magnéto-optique. Un piège magnéto-optique (ou "MOT", de l'anglais magneto-optical trap) est un dispositif qui utilise à la fois le Refroidissement d'atomes par laser et le piégeage magnétique afin de produire des échantillons d'atomes neutres « froids », à des températures pouvant aller jusqu'à quelques microkelvins, à deux ou trois fois la limite de recul du refroidissement Doppler (cf. article principal).
Paper-based microfluidicsPaper-based microfluidics are microfluidic devices that consist of a series of hydrophilic cellulose or nitrocellulose fibers that transport fluid from an inlet through the porous medium to a desired outlet or region of the device, by means of capillary action. This technology builds on the conventional lateral flow test which is capable of detecting many infectious agents and chemical contaminants. The main advantage of this is that it is largely a passively controlled device unlike more complex microfluidic devices.
Organ-on-a-chipAn organ-on-a-chip (OOC) is a multi-channel 3-D microfluidic cell culture, integrated circuit (chip) that simulates the activities, mechanics and physiological response of an entire organ or an organ system. It constitutes the subject matter of significant biomedical engineering research, more precisely in bio-MEMS. The convergence of labs-on-chips (LOCs) and cell biology has permitted the study of human physiology in an organ-specific context.
Refroidissement d'atomes par laservignette|Schéma de refroidissement d'atomes par laser, refroidissement Doppler Le refroidissement d'atomes par laser est une technique qui permet de refroidir un gaz atomique, jusqu'à des températures de l'ordre du mK (refroidissement Doppler), voire de l'ordre du microkelvin (refroidissement Sisyphe) ou encore du nanokelvin. Les gaz ultra-froids ainsi obtenus forment une assemblée d'atomes cohérents, permettant d'accomplir de nombreuses expériences qui n'étaient jusque-là que des expériences de pensée, comme des interférences d'ondes de matière.
Magnetic tweezersMagnetic tweezers (MT) are scientific instruments for the manipulation and characterization of biomolecules or polymers. These apparatus exert forces and torques to individual molecules or groups of molecules. It can be used to measure the tensile strength or the force generated by molecules. Most commonly magnetic tweezers are used to study mechanical properties of biological macromolecules like DNA or proteins in single-molecule experiments. Other applications are the rheology of soft matter, and studies of force-regulated processes in living cells.
Récepteur nucléaireLes récepteurs nucléaires sont une super-famille de récepteurs biochimiques. Ce sont des protéines actives dans le noyau des cellules qui, pour nombre d'entre elles, transmettent à celles-ci des signaux hormonaux spécifiques conduisant à la modulation de l'expression de gènes cibles. Les récepteurs nucléaires sont présents chez tous les métazoaires. La famille est constituée de 49 membres identifiés à ce jour chez l'homme mais de plus d'une centaine toutes espèces confondues.