Edge-enhanced radiology with broadband synchrotron X-rays
Publications associées (85)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Fourier or spectral domain optical coherence tomography (FDOCT) is a multi-dimensional interferometric imaging modality that has attracted increasing interest during the last few years. The reason is its outstanding sensitivity allowing high speed 2D and 3 ...
We have developed a method for X-ray phase contrast imaging, which is based on a grating interferometer. The technique is capable of recording the phase shift of hard X-rays travelling through a sample, which greatly enhances the contrast of low absorbing ...
There is no doubt that optical coherence tomography has become an important biomedical imaging tool today especially due to recent improvements in detection as well as fight source technology. OCT achieves resolution in tissue of a few micrometers and can ...
Ieee Service Center, 445 Hoes Lane, Po Box 1331, Piscataway, Nj 08855-1331 Usa2007
Interventional radiology is a minimally invasive procedure where thin instruments, guidewires and catheters or stents are steered through the patient’s vascular system under X- ray imaging for treatment of vascular diseases. The complexity of these procedu ...
X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics and materials science. For biological tissue samples, polymers or fibre composites, however, the use of conventional X-ray radiography is limited due to their weak absorptio ...
The patented Nanoconverter is as planar flexure-based structure that attenuates linear movement amplitudes by a large constant reduction factor that can be chosen by design typically between 20 and 1000. It allows using conventional commercial actuators wi ...
A focus/detector system of an X-ray apparatus and a method for generating projective or tomographic phase contrast recordings, are disclosed. In an embodiment of the system, the system includes a beam source equipped with a focus and a focus-side source gr ...
Synchrotron‐based X‐ray Tomographic Microscopy (SRXTM) is nowadays a powerful technique for non‐destructive, high‐resolution investigations of a broad kind of materials. High‐brilliance and high‐coherence third generation synchrotron radiation facilities a ...
In the last decade X-ray imaging based on phase contrast greatly advanced thanks to the use of unmonochromatic synchrotron hard X-rays. The recent advances are going beyond microradiology and microtomography to reach nanometre scale. This paper reviews bas ...
One of the main factors that affect the accuracy of intensity-based registration of two-dimensional (2D) X-ray fluoroscopy to three-dimensional (3D) CT data is the similarity measure, which is a criterion function that is used in the registration procedure ...