Abstract

A considerable number of flat slabs supported by columns need to be strengthened against punching shear. Reasons are increasing loads, construction or design errors, but also more stringent code requirements due to the increased knowledge gained in the past years. This paper shows the effects of bonding post-installed shear reinforcement into inclined holes drilled from the bottom of the slab. Laboratory tests have shown that this method not only increases the slab strength but also adds significant deformation capacity. The evaluation of the tests has resulted in a clear design concept based on the critical shear crack theory. First practical implementations have proved that the system can be installed economically at a total cost which is below that of other strengthening methods.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.