Publication

Application of the district cooling/heating network design models in the GLN area

François Maréchal, Luc Girardin, Magnhild Kallhovd
2010
Report or working paper
Abstract

This report present the heating and cooling system integration applied in the GLN area, based on a proposed district cooling/heating network design methodology. The cooling load is provided by a mix of direct cooling and refrigeration. To improve the total performance of the district cooling, a method for optimizing the mass flow of lake water has earlier been developed and implemented for one building in the GLN project. This method has in this project been adjusted and developed so that it can now be used for optimizing the lake mass flow for all the connected buildings of the area. The lake water can also be used as a heat source by implementing heat pumps. To study this option, energy integration techniques were applied to access the potential savings in terms of energy bill and CO2 emissions. A comparison between the situation with and without heat pumps was then carried out. The results show that considerable savings can be achieved regarding energy costs and CO2 emissions, respectively 33% and 79%.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related concepts (32)
Heat pump
A heat pump is a device that uses work to transfer heat from a cool space to a warm space by transferring thermal energy using a refrigeration cycle, cooling the cool space and warming the warm space. In cold weather a heat pump can move heat from the cool outdoors to warm a house; the pump may also be designed to move heat from the house to the warmer outdoors in warm weather. As they transfer heat rather than generating heat, they are more energy-efficient than other ways of heating a home.
Computer cooling
Computer cooling is required to remove the waste heat produced by computer components, to keep components within permissible operating temperature limits. Components that are susceptible to temporary malfunction or permanent failure if overheated include integrated circuits such as central processing units (CPUs), chipsets, graphics cards, and hard disk drives. Components are often designed to generate as little heat as possible, and computers and operating systems may be designed to reduce power consumption and consequent heating according to workload, but more heat may still be produced than can be removed without attention to cooling.
Cooling tower
A cooling tower is a device that rejects waste heat to the atmosphere through the cooling of a coolant stream, usually a water stream, to a lower temperature. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid to near the wet-bulb air temperature or, in the case of dry cooling towers, rely solely on air to cool the working fluid to near the dry-bulb air temperature using radiators.
Show more
Related publications (57)

Performance of energy piles foundation in hot-dominated climate: A case study in Dubai

Lyesse Laloui, Elena Ravera, Sofie Elaine ten Bosch

Energy piles represent an innovative technology that can help provide sustainable geothermal heating or cooling energy for thermal conditioning purposes. In hot-dominated climates, the interest is to inject heat in the ground and extract energy for space-c ...
2024

Design and assessment of an evaporating water-cooled methanation reactor for a SOE-based power-to-methane system

Philippe Aubin

The transition towards clean renewable energy sources, where wind and solar are prone to variation, requires adequate energy storage. Power-to-methane (PtM) systems can be part of the solution. Specifically, solid-oxide-electrolyser (SOE) based PtM systems ...
EPFL2024

Decomposition method to evaluate district heating/cooling network potential at urban scale

François Maréchal, Luc Girardin, Ana Catarina Gouveia Braz, Bingqian Liu, Raphaël Briguet

In this work, a tool to design district heating networks (DHN) is presented and applied to the city of Lausanne as a case study. The evaluation of the buildings’ heat/cooling demand is performed using a Geographic Information System (GIS) database, built f ...
Associazione Italiana Di Ingegneria Chimica2024
Show more
Related MOOCs (8)
SES Swiss-Energyscope
La transition énergique suisse / Energiewende in der Schweiz
SES Swiss-Energyscope
La transition énergique suisse / Energiewende in der Schweiz
Simulation Neurocience
Learn how to digitally reconstruct a single neuron to better study the biological mechanisms of brain function, behaviour and disease.
Show more