Publication

Ultra-high voltage, low power and energy recovering electronics for dielectric elastomer actuators

Abstract

Heart failure is a cardiovascular disease affecting between 1 and 2% of the population of developed countries alone - more than 10 million people - with this number bound to increase due to the ageing of the population. This condition starts to develop itself when the heart is not capable to properly pump the blood in the circulatory system anymore, and it can be due to other cardiovascular diseases, hypertension, heart attacks, etc. When cases become very severe, surgical procedures are then necessary to install cardiac assist devices to help reduce the stress experienced by the heart and allow it to potentially heal itself. However, the devices currently used are bulky and very invasive with risks of infections and rejections.As such, the Center for Artificial Muscles (CAM) was tasked to investigate and develop a new kind of cardiac assist devices which would be much less invasive to install. To do so, the idea envisioned consisted of working with Dielectric Elastomer Actuators (DEAs) which are often nicknamed artificial muscles due to their close resemblance with the natural ones as they, amongst other things, light, thin and can deform themselves significantly. One of the main challenges of working with this technology comes from the fact that DEAs have very uncommon needs concerning the driving electronics. Indeed, to operate to the maximum of their abilities, DEAs require voltages of several thousands of volts - between 5 and 20 kV depending on the actuator - to be applied to them. Currently, these actuators are powered using extremely large and impractical laboratory power supplies which is unacceptable for portable and medical applications. It was therefore critical to investigate and uncover a solution for the electronics so that the DEAs' needs could be met with a system as compact and efficient as possible.Thus, this thesis presents the investigating process followed to obtain in the end an electronics system capable of supplying at least 8 kV to a DEA and recover unused electrical energy stored in the actuator. Process which consisted at first of an investigation of power electronics topologies capable of amplifying a given input voltage to a higher level in order to determine the most suitable one. It was concluded that the DC/DC flyback converter was the best candidate for the job.This was followed by an in depth analysis of the working principle of this converter topology to determine the limiting factors regarding the supply of high voltages. This analysis was confirmed through the development of an analytical model depicting the behavior of the converter when it charges the actuator to the required voltage. Thanks to this a list of solutions to overcome these factors could be given.Then, due to the voltage levels worked with and the necessity to recover the unused electrical energy stored in the actuator, it was revealed that commercially available solutions were scarce to nonexistent to properly control the electronics. As such, control strategies and custom devices were ultimately conceived to resolve this problem.In the end, the final ultra-high voltage bidirectional flyback converter prototype was used to operate a DEA pump placed in a test bench recreating the pressure conditions and blood flow which are expected to be found in a living body. These tests showed that the electronics performed very well and managed to operate without major issues the new cardiac assist device created by the CAM.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related concepts (37)
Ventricular assist device
A ventricular assist device (VAD) is an electromechanical device for assisting cardiac circulation, which is used either to partially or to completely replace the function of a failing heart. The function of a VAD differs from that of an artificial cardiac pacemaker in that a VAD pumps blood, whereas a pacemaker delivers electrical impulses to the heart muscle. Some VADs are for short-term use, typically for patients recovering from myocardial infarction (heart attack) and for patients recovering from cardiac surgery; some are for long-term use (months to years to perpetuity), typically for patients with advanced heart failure.
Heart failure
Heart failure (HF), also known as congestive heart failure (CHF), is a syndrome, a group of signs and symptoms, caused by an impairment of the heart's blood pumping function. Symptoms typically include shortness of breath, excessive fatigue, and leg swelling. The shortness of breath may occur with exertion or while lying down, and may wake people up during the night. Chest pain, including angina, is not usually caused by heart failure, but may occur if the heart failure was caused by a heart attack.
Heart
The heart is a muscular organ in most animals. This organ pumps blood through the blood vessels of the circulatory system. The pumped blood carries oxygen and nutrients to the body, while carrying metabolic waste such as carbon dioxide to the lungs. In humans, the heart is approximately the size of a closed fist and is located between the lungs, in the middle compartment of the chest, called the mediastinum. In humans, other mammals, and birds, the heart is divided into four chambers: upper left and right atria and lower left and right ventricles.
Show more
Related publications (66)

The role of computational methods in cardiovascular medicine: a narrative review

Alfio Quarteroni, Luca Dede', Christian Vergara, Stefano Pagani

Background and Objective: Computational models of the cardiovascular system allow for a detailed and quantitative investigation of both physiological and pathological conditions, thanks to their ability to combine clinical-possibly patient-specific-data wi ...
Ame Publishing Company2024

Ripple Voltage and Loss Reduction of Single-Phase ISOP SST by Eliminating the Second Harmonic Current in LLC Converters

Drazen Dujic, Andrea Cervone, Tianyu Wei

In two-stage solid-state transformers with input-series output-parallel structure, the LLC converter operating at a fixed switching frequency is a common choice for the isolated DC/DC conversion stage because it can provide a high efficiency and a fixed vo ...
2024

Implementation of an epicardial implantable MEMS sensor for continuous and real-time postoperative assessment of left ventricular activity in adult minipigs over a short- and long-term period

Silvestro Micera

The sensing of left ventricular (LV) activity is fundamental in the diagnosis and monitoring of cardiovascular health in high-risk patients after cardiac surgery to achieve better short- and long-term outcome. Conventional approaches rely on noninvasive me ...
Aip Publishing2024
Show more
Related MOOCs (13)
Electronics
Introduction à l’électronique analogique- seconde partie. Fonctions linéaires de base réalisée à l’aide de transistor bipolaire.
Electronics
Introduction à l’électronique analogique- seconde partie. Fonctions linéaires de base réalisée à l’aide de transistor bipolaire.
Electrical Engineering I
Découvrez les circuits électriques linéaires. Apprenez à les maîtriser et à les résoudre, dans un premier temps en régime continu puis en régime alternatif.
Show more

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.