The depletion of fossil fuel sources has encouraged the authorities to use renewable resources such as wind energy to generate electricity. A backup/storage system can improve the performance of wind turbines, due to fluctuations in power demand. The novelty of this study is to utilize a hybrid system for a wind farm, using the excess electricity generated by the wind turbines to produce hydrogen in an alkaline electrolyzer (AEL). The hydrogen storage tank stores the produced hydrogen and provides hydrogen to the proton-exchange membrane fuel cell (PEMFC) to generate electricity once the power demand is higher than the electricity generated by the wind turbines. The goal of this study is to use the wind profile of a region in Iran, namely the Cohen region, to analyze the performance of the suggested integrated system on a micro scale. The output results of this study can be used as a case study for construction in the future, based on the exact specification of NTK300 wind turbines. The results indicate that, with the minimum power supply of 30 kW from the wind turbines on a lab scale, the generated power by the PEMFC will be 1008 W, while the maximum generated hydrogen will be 304 mL/h.