RS-485, also known as TIA-485(-A) or EIA-485, is a standard, originally introduced in 1983, defining the electrical characteristics of drivers and receivers for use in serial communications systems. Electrical signaling is balanced, and multipoint systems are supported. The standard is jointly published by the Telecommunications Industry Association and Electronic Industries Alliance (TIA/EIA). Digital communications networks implementing the standard can be used effectively over long distances and in electrically noisy environments. Multiple receivers may be connected to such a network in a linear, multidrop bus. These characteristics make RS-485 useful in industrial control systems and similar applications.
RS-485 supports inexpensive local networks and multidrop communications links, using the same differential signaling over twisted pair as RS-422. It is generally accepted that RS-485 can be used with data rates up to 10 Mbit/s or, at lower speeds, distances up to . As a rule of thumb, the speed in bit/s multiplied by the length in metres should not exceed 108. Thus a 50-meter cable should not signal faster than 2 Mbit/s.
In contrast to RS-422, which has a driver circuit which cannot be switched off, RS-485 drivers use three-state logic allowing individual transmitters to be deactivated. This allows RS-485 to implement linear bus topologies using only two wires. The equipment located along a set of RS-485 wires are interchangeably called nodes, stations or devices. The recommended arrangement of the wires is as a connected series of point-to-point (multidropped) nodes, i.e. a line or bus, not a star, ring, or multiply connected network. Star and ring topologies are not recommended because of signal reflections or excessively low or high termination impedance. If a star configuration is unavoidable, special RS-485 repeaters are available which bidirectionally listen for data on each span and then retransmit the data onto all other spans.
Ideally, the two ends of the cable will have a termination resistor connected across the two wires.
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
A multidrop bus (MDB) is a computer bus in which all components are connected to the electrical circuit. A process of arbitration determines which device sends information at any point. The other devices listen for the data they are intended to receive. Multidrop buses have the advantage of simplicity and extensibility, but their differing electrical characteristics make them relatively unsuitable for high frequency or high bandwidth applications.
Serial Peripheral Interface (SPI) is a de facto standard (with many variants) for synchronous serial communication, used primarily in embedded systems for short-distance wired communication between integrated circuits. SPI uses a main–subnode architecture, where one main device orchestrates communication by providing the clock signal and chip select signal(s) which control any number of subservient peripherals. Motorola's original specification uses four wires to perform full duplex communication.
A Controller Area Network (CAN bus) is a vehicle bus standard designed to allow microcontrollers and devices to communicate with each other's applications without a host computer. It is a message-based protocol, designed originally for multiplex electrical wiring within automobiles to save on copper, but it can also be used in many other contexts. For each device, the data in a frame is transmitted serially but in such a way that if more than one device transmits at the same time, the highest priority device can continue while the others back off.
To efficiently program embedded systems an understanding of their architectures is required. After following this course students will be able to take an existing SoC, understand its architecture, and
Ce cours propose une introduction aux sciences et technologies de l'électricité en mettant l'accent sur les composants des
circuits électriques. L'enseignement comprend à la fois une partie théorique
This course is an introduction to the theory of Riemann surfaces. Riemann surfaces naturally appear is mathematics in many different ways: as a result of analytic continuation, as quotients of complex
Wireless communications are currently faced with two main challenges. The first challenge stems from the enormous number of Internet of Things (IoT) devices that transmit very small amounts of data. The second challenge is the need for ever-increasing data ...
In Environmental Impact Assessment (EIA), the either positive or negative impacts that specific N project actions might generate on a number M of environmental components are typically summarized in the form of Interaction Matrix (IM). This is an NxM tabul ...
In this paper, three different pseudo resistor (PR) realizations are compared regarding their noise and linearity performance within the DC feedback loop of an integrator-differentiator transimpedance amplifier (I-D-TIA). Thanks to its intrinsic shot noise ...