DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
This paper deals with the calculation of lightning-induced overvoltages on medium-voltage (MV) and low-voltage (LV) distribution networks taking into account the presence of MV-LV distribution transformers and, in particular, the surge transfer through the ...
2009
,
For the case of urban overhead lines, the presence of nearby buildings is expected to affect the overvoltages induced by nearby cloud-to-ground lightning return strokes. So far, this effect has been seldom taken into account in the literature on the subjec ...
Elsevier2013
,
Factors that contribute to lightning-caused faults on the line insulation of overhead distribution lines and suggested improvements to existing and new constructions are identified in this guide. ...
IEEE2011
The aim of the paper is to analyze overvoltages in overhead distribution lines induced by nearby lightning return stroke currents taking into account also the conductive coupling between the lightning current injected into the soil and the line's grounding ...
This design guide contains information on methods to improve the lightning protection performance of overhead distribution lines and is written for the distribution-line designer. This guide recognizes that a perfect line design does not exist and that a s ...
Nowadays medium voltage conversion systems, like traction and energy distribution systems, aim to increase power density. Volume, weight and material reduction are gaining the market today. Due to the development of new high power semiconductor devices a n ...
2008
This paper deals with the assessment of the lightning performance of distribution lines, namely the estimation of the annual number of lightning-induced flashovers versus the critical flashover voltage of the line insulators. The procedure proposed by the ...
2007
, , , ,
In the frame of the European project UNIFLEX-PM, two AC/AC converter topologies hove been studied and implemented. Both converters, rated for 25 kVA, are isolated by a medium-frequency power transformer. The first topology is based on a dual active bridge ...
Lettuce greenhouse experiments were carried out from March to June 2011 in order to analyze how pesticides behave from the time of application until their intake via human consumption taking into account the primary distribution of pesticides, field dissip ...
The drawbacks of conventional Modular Multilevel Converters (MMC) are described in terms of short-circuits. The configuration of MMC-transformer-MMC proves to handle short-circuits at the input and output without the need for additional DC or AC circuit br ...