Luminous efficacy is a measure of how well a light source produces visible light. It is the ratio of luminous flux to power, measured in lumens per watt in the International System of Units (SI). Depending on context, the power can be either the radiant flux of the source's output, or it can be the total power (electric power, chemical energy, or others) consumed by the source.
Which sense of the term is intended must usually be inferred from the context, and is sometimes unclear. The former sense is sometimes called luminous efficacy of radiation, and the latter luminous efficacy of a light source or overall luminous efficacy.
Not all wavelengths of light are equally visible, or equally effective at stimulating human vision, due to the spectral sensitivity of the human eye; radiation in the infrared and ultraviolet parts of the spectrum is useless for illumination. The luminous efficacy of a source is the product of how well it converts energy to electromagnetic radiation, and how well the emitted radiation is detected by the human eye.
Luminous efficacy can be normalized by the maximum possible luminous efficacy to a dimensionless quantity called luminous efficiency. The distinction between efficacy and efficiency is not always carefully maintained in published sources, so it is not uncommon to see "efficiencies" expressed in lumens per watt, or "efficacies" expressed as a percentage.
Wavelengths of light outside of the visible spectrum are not useful for illumination because they cannot be seen by the human eye. Furthermore, the eye responds more to some wavelengths of light than others, even within the visible spectrum. This response of the eye is represented by the luminosity function. This is a standardized function which represents the response of a "typical" eye under bright conditions (photopic vision). One can also define a similar curve for dim conditions (scotopic vision). When neither is specified, photopic conditions are generally assumed.
Luminous efficacy of radiation measures the fraction of electromagnetic power which is useful for lighting.
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
A compact fluorescent lamp (CFL), also called compact fluorescent light, energy-saving light, compact fluorescent tube and chloro fluorescent lamp is a fluorescent lamp designed to replace an incandescent light bulb; some types fit into light fixtures designed for incandescent bulbs. The lamps use a tube that is curved or folded to fit into the space of an incandescent bulb, and a compact electronic ballast in the base of the lamp.
An electrical ballast is a device placed in series with a load to limit the amount of current in an electrical circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps to limit the current through the tube, which would otherwise rise to a destructive level due to the negative differential resistance of the tube's voltage-current characteristic. Ballasts vary greatly in complexity.
High-intensity discharge lamps (HID lamps) are a type of electrical gas-discharge lamp which produces light by means of an electric arc between tungsten electrodes housed inside a translucent or transparent fused quartz or fused alumina arc tube. This tube is filled with noble gas and often also contains suitable metal or metal salts. The noble gas enables the arc's initial strike. Once the arc is started, it heats and evaporates the metallic admixture.
Ce cours traite des divers domaines techniques intervenant dans la conception et la réalisation d'un bâtiment, soit : physique du bâtiment, structures, matériaux, construction et installations techniq
Series of lectures covering the physics of quantum heterostructures (including quantum dots), microcavities and photonic crystal cavities as well as the properties of the main light emitting devices t
The most important clinical diagnostic and therapeutic applications of light will be described. In addition, this course will address the principles governing the interactions between light and biolog
Designing architectural façades that allow sufficient daylight to create visually comfortable and pleasantenvironments is a challenging aspect of building design. It requires accounting for visual comfort anddiscomfort glare risks and understanding the fac ...
Avoiding discomfort glare is one of the critical aspects of maintaining visual comfort, which significantly influences occupants' overall satisfaction with their indoor environment. Discomfort glare prediction models have been developed for various lightin ...
The spectral sensitivity of the average human eye in photopic conditions is represented by the photopic luminosity function V (λ). The CIE has established the photopic luminosity functions for the 2o and 10o visual fields for a standard observer applicable ...