A crowbar circuit is an electrical circuit used for preventing an overvoltage or surge condition of a power supply unit from damaging the circuits attached to the power supply. It operates by putting a short circuit or low resistance path across the voltage output (Vo), like dropping a crowbar across the output terminals of the power supply. Crowbar circuits are frequently implemented using a thyristor, TRIAC, trisil or thyratron as the shorting device. Once triggered, they depend on the current-limiting circuitry of the power supply or, if that fails, the blowing of the line fuse or tripping the circuit breaker. An example crowbar circuit is shown to the right. This particular circuit uses an LM431 adjustable zener regulator to control the gate of the TRIAC. The resistor divider of R1 and R2 provide the reference voltage for the LM431. The divider is set so that during normal operating conditions, the voltage across R2 is slightly lower than VREF of the LM431. Since this voltage is below the minimum reference voltage of the LM431, it remains off and very little current is conducted through the LM431. If the cathode resistor is sized accordingly, very little voltage will be dropped across it and the TRIAC gate terminal will be essentially at the same potential as MT1, keeping the TRIAC off. If the supply voltage increases, the voltage across R2 will exceed VREF and the LM431 cathode will begin to draw current. The voltage at the gate terminal will be pulled down, exceeding the gate trigger voltage of the TRIAC and latching it on. A crowbar circuit is distinct from a clamp in pulling, once triggered, the voltage below the trigger level, usually close to ground voltage. A clamp prevents the voltage from exceeding a preset level. Thus, a crowbar will not automatically return to normal operation when the overvoltage condition is removed; power must be removed entirely to allow the crowbar to return to its neutral state. An active crowbar is a crowbar that can remove the short circuit when the transient is over thus allowing the device to resume normal operation.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related courses (1)
EE-371: Power distribution networks
Le cours a pour objectif de présenter les éléments principaux relatifs à la conception et l¿exploitation des réseaux électriques de distribution (moyenne et basse tension) tout en tenant compte de la
Related lectures (1)
Related publications (4)
Related concepts (2)
Zener diode
A Zener diode is a special type of diode designed to reliably allow current to flow "backwards" (inverted polarity) when a certain set reverse voltage, known as the Zener voltage, is reached. Zener diodes are manufactured with a great variety of Zener voltages and some are even variable. Some Zener diodes have an abrupt, heavily doped p–n junction with a low Zener voltage, in which case the reverse conduction occurs due to electron quantum tunnelling in the short distance between p and n regions − this is known as the Zener effect, after Clarence Zener.
Fuse (electrical)
In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby stopping or interrupting the current. It is a sacrificial device; once a fuse has operated it is an open circuit, and must be replaced or rewired, depending on its type. Fuses have been used as essential safety devices from the early days of electrical engineering.

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.