The Nichols plot is a plot used in signal processing and control design, named after American engineer Nathaniel B. Nichols.
Given a transfer function,
with the closed-loop transfer function defined as,
the Nichols plots displays versus . Loci of constant and are overlaid to allow the designer to obtain the closed loop transfer function directly from the open loop transfer function. Thus, the frequency is the parameter along the curve. This plot may be compared to the Bode plot in which the two inter-related graphs - versus and versus ) - are plotted.
In feedback control design, the plot is useful for assessing the stability and robustness of a linear system. This application of the Nichols plot is central to the quantitative feedback theory (QFT) of Horowitz and Sidi, which is a well known method for robust control system design.
In most cases, refers to the phase of the system's response. Although similar to a Nyquist plot, a Nichols plot is plotted in a Cartesian coordinate system while a Nyquist plot is plotted in a Polar coordinate system.
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Provides the students with basic notions and tools for the analysis of dynamic systems. Shows them how to develop mathematical models of dynamic systems and perform analysis in time and frequency doma
Le but de ce cours est d'apporter les connaissances et les expériences fondamentales pour comprendre les systèmes électriques et électroniques de base.
Les concepts de base permettant de comprendre, d'analyser et de concevoir les circuits à base d'AmpliOp, dédiés à l'acquisition et conditionnement des signaux analogiques sont traités en théorie et pr
In control theory and stability theory, the Nyquist stability criterion or Strecker–Nyquist stability criterion, independently discovered by the German electrical engineer Felix Strecker at Siemens in 1930 and the Swedish-American electrical engineer Harry Nyquist at Bell Telephone Laboratories in 1932, is a graphical technique for determining the stability of a dynamical system.
In electrical engineering and control theory, a Bode plot ˈboʊdi is a graph of the frequency response of a system. It is usually a combination of a Bode magnitude plot, expressing the magnitude (usually in decibels) of the frequency response, and a Bode phase plot, expressing the phase shift. As originally conceived by Hendrik Wade Bode in the 1930s, the plot is an asymptotic approximation of the frequency response, using straight line segments.
In engineering, a transfer function (also known as system function or network function) of a system, sub-system, or component is a mathematical function that models the system's output for each possible input. They are widely used in electronic engineering tools like circuit simulators and control systems. In some simple cases, this function can be represented as two-dimensional graph of an independent scalar input versus the dependent scalar output, called a transfer curve or characteristic curve.
Even though there has been numerous works performed based on electrochemical impedance spectroscopy (EIS) of perovskite solar cells (PSCs), however, many aspects of the obtained EI spectra are yet to be fully grasped. Moreover, the change of these spectra ...
Previous studies have shown the existence of a vertical micro-distribution of testate amoebae in the first centimeters of Sphagnum and their response to nutrient enrichment. In order to test the response of testate amoebae to depth and N addition in dry mo ...
[1] Methane fluxes were measured at five sites representing oligotrophic peatlands along a European transect. Five study plots were subjected to elevated CO2 concentration (560 ppm), and five plots to NH4NO3 (3 or 5 g N yr(-1)). The CH4 emissions from the ...