DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Recent advances in refrigerant-oil flow boiling research are reviewed together with identification of the important trends in published experimental data, while shortcomings in data reduction methods used in most of these previous tests are also noted. New ...
Flow boiling experiments for two new non-azeotropic, three-component refrigerant mixtures (HP80 and HP62) and R-502, the azeotropic refrigerant binary mixture they are replacing, have been carried. Comparative results show that local flow boiling heat tran ...
Flow boiling experiments for two new non-azeotropic, three-component refrigerant mixtures (HP80 and HP62) and R-502 have been carried out inside a 12 mm bore, horizontal tube. Local boiling coefficients for HP62 are slightly larger that those for R-502 und ...
The conversion to the new alternative refrigerants caused by the greenhouse and ozone effects is now replacing nuclear reactor analysis and safety as the major driving force in two-phase heat transfer research. Extensive studies are underway on pool boilin ...
The aim of this work is to extend the investigation, to the influence of lubricating oil on R22-oil mixture in the heat pump and refrigeration system. The refrigerant-oil test bed was modified to accommodate R22-oil mixture investigation and R22-oil solubi ...
Flow pattern data for horizontal intube flow boiling are presented for refrigerants R-134a and R-402 (60/2/38). The flow pattern observations were compared with various criteria for determining whether the entire circumference of a horizontal evaporator tu ...
Intube flow boiling experiments for two new zeotropic refrigerant mixtures and R-502 have been carried out at three saturation temperatures over a wide range of local vapor qualities. The zeotropic mixtures tested were HP80 and HP62. Local flow boiling coe ...
The substitution of old refrigerants in refrigeration systems, heat pumps and organic Rankine cycles for heat recovery, request a good knowledge of heat transfer properties of substitute fluids. The test measurmements in LENI test facility (concentric tube ...
The Ag ion-catalyzed ring-opening of a 1:4 mixt. of syn- and anti-cyclopropanes I and II gave the expected mixt. of CH2:CFC(OH)MeCMe3 and (Z)-MeC(CMe3):CFCH2OH in 56 and 19% yield, resp. Under similar conditions spiro analog. III underwent Wagner-Meerwein ...