An arc lamp or arc light is a lamp that produces light by an electric arc (also called a voltaic arc). The carbon arc light, which consists of an arc between carbon electrodes in air, invented by Humphry Davy in the first decade of the 1800s, was the first practical electric light. It was widely used starting in the 1870s for street and large building lighting until it was superseded by the incandescent light in the early 20th century. It continued in use in more specialized applications where a high intensity point light source was needed, such as searchlights and movie projectors until after World War II. The carbon arc lamp is now obsolete for most of these purposes, but it is still used as a source of high intensity ultraviolet light. The term is now used for gas discharge lamps, which produce light by an arc between metal electrodes through a gas in a glass bulb. The common fluorescent lamp is a low-pressure mercury arc lamp. The xenon arc lamp, which produces a high intensity white light, is now used in many of the applications which formerly used the carbon arc, such as movie projectors and searchlights. An arc is the discharge that occurs when a gas is ionized. A high voltage is pulsed across the lamp to "ignite" or "strike" the arc, after which the discharge can be maintained at a lower voltage. The "strike" requires an electrical circuit with an igniter and a ballast. The ballast is wired in series with the lamp and performs two functions. First, when the power is first switched on, the igniter/starter (which is wired in parallel across the lamp) sets up a small current through the ballast and starter. This creates a small magnetic field within the ballast windings. A moment later the starter interrupts the current flow from the ballast, which has a high inductance and therefore tries to maintain the current flow (the ballast opposes any change in current through it); it cannot, as there is no longer a 'circuit'.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related courses (9)
PHYS-702: Advanced Quantum Field Theory
The course builds on the course QFT1 and QFT2 and develops in parallel to the course on Gauge Theories and the SM.
EE-110: Logic systems (for MT)
Ce cours couvre les fondements des systèmes numériques. Sur la base d'algèbre Booléenne et de circuitscombinatoires et séquentiels incluant les machines d'états finis, les methodes d'analyse et de syn
PHYS-431: Quantum field theory I
The goal of the course is to introduce relativistic quantum field theory as the conceptual and mathematical framework describing fundamental interactions.
Show more
Related lectures (38)
Quantum Field Theory: Path Integrals
Explores path integrals in quantum field theory, emphasizing the significance of Wick rotation and the classical case.
General Fields: Lorentz Representations
Covers the representation of Lorentz transformations through general fields and the consequences of symmetry.
Elevator Logic Systems
Explores elevator logic systems, including behavior analysis, logic functions, SR-Latches, and Set-Reset Latches.
Show more
Related publications (33)

Printed ecoresorbable temperature sensors for environmental monitoring

Danick Briand, Nicolas Francis Fumeaux, James Alec Pierce Bourely, Melissa Kossairi

Abstract Electronic waste has become a pressing issue, necessitating sustainable solutions for the disposal of electronic devices. While the development of environmentally degradable electronics has gained attention, the fabrication of stable and performan ...
2023

Comparison of JET-C DD neutron rates independently predicted by the ASCOT and TRANSP Monte Carlo heating codes

Henri Weisen

Simulations of the DD neutron rates predicted by the ASCOT and TRANSP Monte Carlo heating codes for a diverse set of JET-C (JET with carbon plasma facing components) plasmas are compared. A previous study (Weisen et al 2017 Nucl. Fusion 57 076029) of this ...
IOP Publishing Ltd2022

Spatial coherence properties of an LED-based illumination system for mask-aligner lithography

Hans Peter Herzig, Toralf Scharf, Wilfried Noell, Raoul Kirner, Johana Bernasconi

A high-power LED-based illumination system has been developed as a replacement for the mercury arc lamps used in mask-aligner lithography. LEDs are arranged in a grid array and placed in the entrance aperture of individual reflectors. Those reflectors decr ...
SPIE2019
Show more
Related concepts (18)
Electric arc
An electric arc (or arc discharge) is an electrical breakdown of a gas that produces a prolonged electrical discharge. The current through a normally nonconductive medium such as air produces a plasma, which may produce visible light. An arc discharge is initiated either by thermionic emission or by field emission. After initiation, the arc relies on thermionic emission of electrons from the electrodes supporting the arc. An arc discharge is characterized by a lower voltage than a glow discharge.
Fluorescent lamp
A fluorescent lamp, or fluorescent tube, is a low-pressure mercury-vapor gas-discharge lamp that uses fluorescence to produce visible light. An electric current in the gas excites mercury vapor, which produces short-wave ultraviolet light that then causes a phosphor coating on the inside of the lamp to glow. A fluorescent lamp converts electrical energy into useful light much more efficiently than an incandescent lamp. The typical luminous efficacy of fluorescent lighting systems is 50–100 lumens per watt, several times the efficacy of incandescent bulbs with comparable light output.
Mercury-vapor lamp
A mercury-vapor lamp is a gas-discharge lamp that uses an electric arc through vaporized mercury to produce light. The arc discharge is generally confined to a small fused quartz arc tube mounted within a larger soda lime or borosilicate glass bulb. The outer bulb may be clear or coated with a phosphor; in either case, the outer bulb provides thermal insulation, protection from the ultraviolet radiation the light produces, and a convenient mounting for the fused quartz arc tube.
Show more

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.