A solar chimney - often referred to as a thermal chimney - is a way of improving the natural ventilation of buildings by using convection of air heated by passive solar energy. A simple description of a solar chimney is that of a vertical shaft utilizing solar energy to enhance the natural stack ventilation through a building.
The solar chimney has been in use for centuries, particularly in the Middle East and Near East by the Persians, as well as in Europe by the Romans.
In its simplest form, the solar chimney consists of a black-painted chimney. During the day solar energy heats the chimney and the air within it, creating an updraft of air in the chimney. The suction created at the chimney's base can be used to ventilate and cool the building below. In most parts of the world it is easier to harness wind power for such ventilation as with a windcatcher, but on hot windless days a solar chimney can provide ventilation where otherwise there would be none.
There are however a number of solar chimney variations. The basic design elements of a solar chimney are:
The solar collector area: This can be located in the top part of the chimney or can include the entire shaft. The orientation, type of glazing, insulation and thermal properties of this element are crucial for harnessing, retaining and utilizing solar gains.
The main ventilation shaft: The location, height, cross section and the thermal properties of this structure are also very important.
The inlet and outlet air apertures: The sizes, location as well as aerodynamic aspects of these elements are also significant.
A principle has been proposed for solar power generation, using a large greenhouse at the base rather than relying solely on heating the chimney itself. (For further information on this issue, see Solar updraft tower.)
Solar chimneys are painted black so that they absorb the sun's heat more effectively. When the air inside the chimney is heated, it rises and pulls cold air out from under the ground via the heat exchange tubes.
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Ce cours traite des divers domaines techniques intervenant dans la conception et la réalisation d'un bâtiment, soit: physique du bâtiment, structures et matériaux, construction et installations techni
Introduction aux phénomènes propagatifs dans les circuits hydrauliques, calculs de coups de béliers, comportement transitoire d'aménagements hydroélectriques, simulation numériques 1D du comportement
Delves into IAQ controls, covering ventilation strategies, filtration, and air cleaning, emphasizing the impact of indoor climate on human health and productivity.
Aerosol transmission remains a major challenge for the control of respiratory viruses. To date, prevention strategies include masks, vaccinations, physical distancing, travel restrictions, and lockdowns. Such measures are effective but come with heavy soci ...
Hoboken2023
Related units (2)
,
Residential ventilative cooling via natural ventilation is influenced by outdoor air pollution. However, relative to climate, outdoor air pollution is not comprehensively considered in determining the ventilative cooling potential of buildings. To assess t ...
Modern health and productivity concerns related to air pollutant exposure in buildings have sparked the need for occupant-centric monitoring and ventilation control. The existing personal exposure monitoring is often restricted to stationary air quality se ...
Passive cooling is a building design approach that focuses on heat gain control and heat dissipation in a building in order to improve the indoor thermal comfort with low or no energy consumption. This approach works either by preventing heat from entering the interior (heat gain prevention) or by removing heat from the building (natural cooling). Natural cooling utilizes on-site energy, available from the natural environment, combined with the architectural design of building components (e.g.
A windcatcher, wind tower, or wind scoop (ملقف, بادگیر) is a traditional architectural element used to create cross ventilation and passive cooling in buildings. Windcatchers come in various designs, depending on whether local prevailing winds are unidirectional, bidirectional, or multidirectional, on how they change with altitude, on the daily temperature cycle, on humidity, and on how much dust needs to be removed. Despite the name, windcatchers can also function without wind.
The stack effect or chimney effect is the movement of air into and out of buildings through unsealed openings, chimneys, flue-gas stacks, or other containers, resulting from air buoyancy. Buoyancy occurs due to a difference in indoor-to-outdoor air density resulting from temperature and moisture differences. The result is either a positive or negative buoyancy force. The greater the thermal difference and the height of the structure, the greater the buoyancy force, and thus the stack effect.