Lightning protection of distribution networks. Part II: Application to MV networks
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The paper investigates the applicability of some closed form expressions for the ground impedance and ground admittance of buried horizontal wires (bare and insulated) for lightning or switching transient analyses based on transmission line (TL) theory. In ...
The evaluation of electromagnetic transients in overhead power lines due to nearby lightning return strokes requires accurate models for the calculation of both the incident lightning electromagnetic pulse ( LEMP) and the effects of coupling of this field ...
Monitoring units for the measurement of high frequencyvoltage transients have been in operation at three different busses of an Italian medium voltage (MV) distribution feeder, mainly composed by overhead lines, in March 2007 – August 2008. The feeder is l ...
This paper deals with scale models of power distribution systems for the study of lightning induced voltages on overhead lines. The scale model technique is useful for the investigation of situations which are prohibitively complex to be treated theoretica ...
The paper deals with the correlation between lightning and distribution networks faults and/or voltage dips. In particular, the paper presents an application of a method proposed by the authors to correlate lightning events and relays operations based on t ...
The paper deals with the evaluation of the indirect-lightning performance of overhead distribution networks. The novelty of this contribution is that it takes into account the inherent complexity of distribution networks. These networks are indeed characte ...
For an improved assessment of the indirect-lightning performances of distribution systems, the real configuration of the system, which means the topology, the presence of protection devices such as surge arresters and shielding wire/neutral groundings, mus ...
This paper deals with the calculation of lightning-induced overvoltages on medium-voltage (MV) and low-voltage (LV) distribution networks taking into account the presence of MV-LV distribution transformers and, in particular, the surge transfer through the ...
The aim of this paper is to present the results of the performance study of medium voltage overhead distribution lines against lightning discharges, in the way to define methodologies to reduce the system failures. The results are obtained within the partn ...
The DC performances of three full- and five sub-size NbTi cable-in-conduit conductors, measured in the SULTAN test facility, are compared. In general, the self-field effect was found to cause sudden take-offs at high currents. In most of the investigated c ...