Estimates of lightning-induced voltage stresses within buried shielded conduits
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Lightning currents and electromagnetic fields associated with return strokes to elevated strike objects The aim of this thesis is the modeling of lightning return strokes impacting elevated strike objects such as towers. The theoretical and experimental wo ...
Voltage transients are the main causes of complaints from medium-voltage customers. For this reason, utilities and independent authorities are focusing their attention on investigation techniques capable of providing information useful for classifying volt ...
In this paper, we investigate the effect of periodically-grounded shielding wires and surge arresters on the attenuation of lightning-induced voltages. We discuss the adequacy of the commonly made simplification of assuming the shielding wire at ground pot ...
The statistical assessment of the lightning-performances of distribution lines must take into account the presence of protection devices such as surge arresters and shielding wire/neutral groundings. Indeed, the presence of those devices does modify the in ...
Although, due to the high variability of key parameters such as the return-stroke speed, it is impossible to determine the lightning current accurately from the remotely measured electric or magnetic field for a given event, we show in this paper that, for ...
Recent power quality studies have been focused on the source-identification of voltage disturbances at distribution network busses. This paper describes a method aimed at correlating indirect-lightning events with power systems relay operations, associated ...
The appraisal of the response of distribution networks to the excitation of lightning electro magnetic pulse (LEMP) requires the availability of accurate models of LEMP-illuminated lines. These models should be able to take into account the presence of shi ...
Since 1991, a broadband, high-resolution current measurement system has captured the lightning current derivative at the Toronto CN Tower. In this paper, extensive statistics (1992-2001) of CN Tower lightning current waveform parameters (maximum steepness ...
We present in this paper experimental results obtained at the International Center for Lightning Research and Testing (ICLRT), Camp Blanding, Florida, where currents induced by triggered and natural lightning events were measured at one end of a shielded b ...
Voltage sags are one of major concerns in power quality, as they cause serious malfunction of a large number of apparatuses. There are a number of reasons for voltage sags in distribution networks: there is some evidence, however, that in electrical system ...