Are you an EPFL student looking for a semester project?
Work with us on data science and visualisation projects, and deploy your project as an app on top of GraphSearch.
In a centrifugal pump the interaction between the rotating impeller pressure field and the stationary diffuser pressure field yields pressure fluctuations as the result of a modulation process. These fluctuations may induce hydroacoustic pressure fluctuations in the exit chamber of the pump and could cause %under resonance conditions% unacceptable vibrations. This paper presents a methodology for the prediction of hydroacoustic pressure fluctuations resulting from rotor-stator interaction in a multistage centrifugal pump. The method consists in the one-way coupling of incompressible CFD and hydroacoustic simulations. In a first step the rotor-stator pressure fluctuations are calculated using a commercial 3D-RANS CFD-code (CFX 10) for different flow rates. The acoustic simulations are performed in two consecutive steps. Initially a free oscillation analysis using white noise pressure fluctuations is performed, which provides hydroacoustic eigen frequencies and mode shapes of the outlet casing. In a second step the spatially distributed pressure fluctuations from the CFD simulation are used to perform a forced oscillation analysis. This approach allows the prediction of possible standing waves in the hydraulic collection elements in the last stage of multistage pumps.
Loading
Loading
Loading
François Avellan, Stefan Berten, Philippe Dupont, Laurent Fabre, Mohamed Farhat, Maher Kayal