The toroidal Field Conductor Insert (TFCI) coil was tested at 46 kA in the 13 T background magnetic field generated by the Central Solenoid Model Coil. The single layer TFCI coil uses a Nb3Sn cable-in-conduit conductor in a Titanium jacket. The object of this work is to verify the data self-consistency, and to apply a thermal, hydraulic and electrical simulation to derive the strand performance in the cable. We present the results of the analysis in support of the interpretation of a subset of current sharing temperature measurements. After estimation of the n-value in the voltage-current equation, we perform the simulations using the total longitudinal strain as the only fitting parameter; the resulting value is much larger than the value expected from simple thermal contraction considerations.
Rainer Wesche, Roberto Guarino, Frédéric Michel