Flow boiling in horizontal smooth tubes: New heat transfer results for R-134a at three saturation temperatures
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
This article presents experimental results of heat transfer from two different studies [1, 2] for horizontal flow boiling inside smooth copper tubes with different refrigerants. The main goal of this study was to verify the influence of the saturation temp ...
The current industrial need for compact high heat density cooling devices has conveyed an increasing interest on convective boiling in micro-channels. Although there is general agreement that these systems may be able to dissipate potentially very high hea ...
Temperature highly affects pavement performance. High and low temperatures not only affects the viscosity of asphalt concrete but also has an impact on the moisture flow within pavements. At temperatures below 0°C the freezing of pavements dramatically cha ...
Experiments of diabatic two-phase pressure drops in flow boiling were conducted in four horizontal flattened smooth copper tubes with two different heights of 2 and 3 mm. The equivalent diameters of the flat tubes are 8.6, 7.17. 6.25, and 5.3 mm. The worki ...
A comprehensive review of flow boiling characteristics and flow pattern visualization of refrigerant/lubricant oil mixtures is presented in this paper. First, various parameters influenced by the lubricant oil in convective boiling of refrigerants, such as ...
The rapid development of micro-thermal technologies has conveyed an increasing interest on convective boiling in micro-channels. Although there is general agreement that these systems may be able to dissipate potentially very high heat fluxes per unit volu ...
New saturated critical heat flux (CHF) data have been obtained experimentally in two different multi-microchannel heat sinks made in copper with three low pressure refrigerants (R134a, R236fa, R245fa). One of the test sections had 20 parallel rectangular c ...
This research focuses on acquiring accurate flow boiling heat transfer data and flow pattern visualization for three refrigerants, R134a, R236fa and R245fa in a 1.030 mm channel. We investigate trends in the data, and their possible mechanisms, for mass fl ...
A new falling film heat transfer test facility has been built for the measurement of local heat transfer coefficients on a vertical array of horizontal tubes, including flow visualization capabilities, for use with refrigerants. Presently, the facility has ...
In tune with the falling film evaporation heat transfer test results described in Part 1, flow visualization of the boiling process and intertube flow mode transitions from droplet to column and sheet flows have been observed, and the onset of dryout resul ...