Flow boiling in horizontal smooth tubes: New heat transfer results for R-134a at three saturation temperatures
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The rapid development of micro-thermal technologies has conveyed an increasing interest on convective boiling in micro-channels. Although there is general agreement that these systems may be able to dissipate potentially very high heat fluxes per unit volu ...
Experiments of diabatic two-phase pressure drops in flow boiling were conducted in four horizontal flattened smooth copper tubes with two different heights of 2 and 3 mm. The equivalent diameters of the flat tubes are 8.6, 7.17. 6.25, and 5.3 mm. The worki ...
This research focuses on acquiring accurate flow boiling heat transfer data and flow pattern visualization for three refrigerants, R134a, R236fa and R245fa in a 1.030 mm channel. We investigate trends in the data, and their possible mechanisms, for mass fl ...
This article presents experimental results of heat transfer from two different studies [1, 2] for horizontal flow boiling inside smooth copper tubes with different refrigerants. The main goal of this study was to verify the influence of the saturation temp ...
A comprehensive review of flow boiling characteristics and flow pattern visualization of refrigerant/lubricant oil mixtures is presented in this paper. First, various parameters influenced by the lubricant oil in convective boiling of refrigerants, such as ...
New saturated critical heat flux (CHF) data have been obtained experimentally in two different multi-microchannel heat sinks made in copper with three low pressure refrigerants (R134a, R236fa, R245fa). One of the test sections had 20 parallel rectangular c ...
The current industrial need for compact high heat density cooling devices has conveyed an increasing interest on convective boiling in micro-channels. Although there is general agreement that these systems may be able to dissipate potentially very high hea ...
In tune with the falling film evaporation heat transfer test results described in Part 1, flow visualization of the boiling process and intertube flow mode transitions from droplet to column and sheet flows have been observed, and the onset of dryout resul ...
Temperature highly affects pavement performance. High and low temperatures not only affects the viscosity of asphalt concrete but also has an impact on the moisture flow within pavements. At temperatures below 0°C the freezing of pavements dramatically cha ...
A new falling film heat transfer test facility has been built for the measurement of local heat transfer coefficients on a vertical array of horizontal tubes, including flow visualization capabilities, for use with refrigerants. Presently, the facility has ...