Improved Turbulence Profiling with Field-Adapted Acoustic Doppler Velocimeters Using a Bifrequency Doppler Noise Suppression Method

Ulrich Lemmin, David Hurther
2008
Journal paper
Abstract

A novel noise reduction method and corresponding technique are presented for improving turbulence measurements with acoustic Doppler velocimeters (ADVs) commonly used in field studies of coastal and nearshore regions, rivers, lakes, and estuaries. This bifrequency method is based on the decorrelation of the random and statistically independent Doppler noise terms contained in the Doppler signals at two frequencies. It is shown through experiments in an oscillating grid turbulence (OGT) tank producing diffusive isotropic turbulence that a shift in carrier frequency of less than 10% is sufficient to increase the resolved frequency range by a decade in the turbulent velocity spectra. Over this spectral range, the slope of the velocity spectra agrees well with the universal inertial range value of −5/3. The limit due to spatial averaging effects over the sample volume can be determined from the abrupt deviation of the spectral slope from the −5/3 value. As a result, the relative error of the turbulent intensity estimate and the turbulent kinetic energy (TKE) dissipation rate, measured by two different methods, does not exceed 10% in the case of isotropic turbulence. Furthermore, the bifrequency method allows accurate estimates of the turbulent microscales as shown by the good agreement of the ratio between the Taylor and Kolmogorov microscales and an Re14{Re}^{\frac{1}{4}} power law. Compared to previous Doppler noise reduction methods (Garbini et al.), an increase in time resolution by a factor of 4 is achieved. The proposed method also avoids the loss of TKE energy contained in isotropic flow structures of size equal to and smaller than the sample volume. Different from Doppler noise methods proposed by Hurther and Lemmin and Blanckaert and Lemmin, this method does not require additional hardware components, electronic circuitry, or sensors because the redundant instantaneous velocity field information is captured with the same transducer. The required shift in carrier frequency is small enough for the bifrequency method to be easily implemented in commercial ADVs.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.