Publication

Design and Development of a Miniaturised Total Chemical Anylysis System for on-line Lactate and Glucus Monitoring in Biological samples

Related publications (41)

Frequency response of fiber reinforced DEAs

Yves Perriard, Yoan René Cyrille Civet, Thomas Guillaume Martinez, Stefania Maria Aliki Konstantinidi, Markus Koenigsdorff

Dielectric Elastomer Actuators (DEAs) have emerged as versatile and promising devices for a multitude of applications, including soft robotics, haptic interfaces, and artificial muscles. DEAs are an interesting soft actuator technology due to their high en ...
Society of Photo-Optical Instrumentation Engineers (SPIE)2024

Printed ecoresorbable temperature sensors for environmental monitoring

Danick Briand, Nicolas Francis Fumeaux, James Alec Pierce Bourely, Melissa Kossairi

Abstract Electronic waste has become a pressing issue, necessitating sustainable solutions for the disposal of electronic devices. While the development of environmentally degradable electronics has gained attention, the fabrication of stable and performan ...
2023

Single photon detection with amorphous silicon-based microchannel plates: A Monte Carlo model

Christophe Ballif, Jonathan Emanuel Thomet, Janina Christine Isabelle Löffler, Samira Alexandra Frey

Microchannel plates based on amorphous silicon have the inherent capability to overcome the existing spatial and temporal resolution limitations of single photon detectors. A Monte Carlo model-based study is presented here that serves to exploit their full ...
2022

Fiber-Tip Polymer Microcantilever for Fast and Highly Sensitive Hydrogen Measurement

Giovanni Dietler, Sandor Kasas, Jiangtao Zhou, Leonardo Venturelli, Yiping Wang, Chaohui Li, Meng Zhu, Cong Xiong

Hydrogen as an antioxidant gas has been widely used in the medical and biological fields for preventing cancer or treating inflammation. However, controlling the hydrogen concentration is crucial for practical use due to its explosive property when its vol ...
AMER CHEMICAL SOC2020

Real-Time Multi-Ion Detection in the Sweat Concentration Range Enabled by Flexible, Printed, and Microfluidics-Integrated Organic Transistor Arrays

Danick Briand, Silvia Demuru, Brince Paul Kunnel

Organic electrochemical transistors (OECTs) show remarkable promise as biosensors, thanks to their high signal amplification, simple architecture, and the intrinsic flexibility of the organic material. Despite these properties, their use for real-time sens ...
WILEY2020

Design and Optimization of a Low Power and Fast Response Viscometer Used for Determination of the Natural Gas Wobbe Index

Danick Briand, Pierre-André Farine, Gaël André Léon Farine, Conor Joseph Slater, Marjan Shaker

This paper reports on the design of a microsystem-based thermal gas viscometer used for the determination of the quality of natural gas and its optimization through modification of its two main components: the hotplate and the capillary tube. Features, suc ...
2019

High voltage metal oxide thin film transistors to drive arrays of dielectric elastomer actuators

Alexis Pierre Henri Marette

This thesis advances the field of high-voltage thin film transistors (HVTFTs) and dielectric elastomer actuators (DEAs) by demonstrating a strategy for low-voltage addressing of an array of high voltage soft actuators suspended on a flexible substrate. Fi ...
EPFL2018

Latency and Backlog Bounds in Time-Sensitive Networking with Credit Based Shapers and Asynchronous Traffic Shaping

Jean-Yves Le Boudec, Eleni Stai, Ehsan Mohammadpour, Maaz Mashood Mohiuddin

We compute bounds on end-to-end worst-case latency and on nodal backlog size for a per-class deterministic network that implements Credit Based Shaper (CBS) and Asynchronous Traffic Shaping (ATS), as proposed by the Time-Sensitive Networking (TSN) standard ...
IEEE2018

Analysis and Reduction of Time Response in Thermally Activated Shape Memory Alloys

Yves Perriard, Yoan René Cyrille Civet, Mario Joe Lehmann, Raphaël Johannes Charles Mottet, Sean Thomas

This paper aims to study the factors that affect the time response of Shape Memory Alloys (SMA) and establish a method to improve their activation times. In this work, different parameters such as the number, positions and orientation of the perforations o ...
2018

An IoT Solution for Online Monitoring of Anesthetics in Human Serum Based on an Integrated Fluidic Bioelectronic System

Giovanni De Micheli, Sandro Carrara, Francesca Stradolini, Danilo Demarchi, Tugba Kilic, Abuduwaili Tuoheti, Sofia Lydia Ntella, Nadia Tamburrano, Zijian Huang

In this paper, we present the design, the implementation and the validation of a novel Internet of Things (IoT) drug monitoring system for the online continuous and simultaneous detection of two main anesthetics, e.g., propofol and paracetamol, in undilute ...
2018

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.