The impact of the E46K mutation on the properties of alpha-synuclein in its monomeric and oligomeric states
Related publications (35)
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Information for phase identification may be gathered in the electron transmission microscope with spatial resolution down to the nanometre scale. Energy dispersive X-ray and electron energy loss spectrometries are based on inelastic electron/sample interac ...
The measurement of circular dichroism in the electron microscope is a new, emerging method and, as such, it is subject to constant refinement and improvement. Different ways can be envisaged to record the signal. We present an overview of the key steps in ...
A method for preparing and observing clay platelets for size and shape analysis using scanning electron microscopy (SEM) was developed. Samples of the clay platelets were prepared by polyelectrolyte-assisted adsorption onto a pyrolytic graphite surface. Th ...
A W-2Y(2)O(3) composite has been developed by powder metallurgy methods in collaboration with the Plansee Company (Austria). The microstructure of the composite was analyzed using transmission electron microscopy and electron backscatter diffraction in sca ...
The stochastic nature of biological systems makes the study of individual cells a necessity in systems biology. Yet, handling and disruption of single cells and the analysis of the relatively low concentrations of their protein components still challenges ...
Collagen type I displays a typical banding periodicity of 67 nm when visualized by atomic force or transmission electron microscopy imaging. We have investigated collagen fibers extracted from rat tail tendons using atomic force microscopy, under different ...
Although the analogies between the electron energy loss spectra and X-ray absorption spectra were recognized long ago, the possibility to observe the magnetic circular dichroism in the electron microscope was demonstrated only recently. This technique comb ...
Building upon the similarities between inelastic electron scattering and X-ray absorption we show that dichroism can be observed in electron energy loss spectrometry (EELS) in the transmission electron microscope (TEM). Natural or magnetic linear dichroism ...
The core–shell structure of a range of acrylic–acrylic latexes has been investigated by combining different specimen preparation methods with transmission electron microscopy (TEM), dark-field scanning transmission electron microscopy (DSTEM) and low-volta ...
Zircaloy-4 has been oxidised in environmental scanning electron microscope (ESEM), at a temperature of 700 °C and the surface of the material has been observed during the oxidation, directly in the ESEM. The material has been subsequently analysed by atomi ...