Wireless contact lens sensor for intra ocular pressure monitoring: assessment on enucleated pig eyes

Abstract

Purpose: Assessment on enucleated pig eyes of a novel and minimally invasive method for the continuous monitoring of intraocular pressure (IOP), based on a novel wireless contact lens sensor (CLS). Methods: The wireless CLS is a disposable silicone soft contact lens with a sensor embedded in it, allowing the wireless measurement of changes in corneal curvature induced by IOP variations. A CLS was adapted and tested on enucleated pig eyes. To demonstrate the measurement principle of the device, the enucleated pig eye was cannulated, allowing precise control of IOP. The CLS signal was then compared to the imposed IOP. Results: First, the IOP of enucleated pig eyes was changed between 11 and 14 mmHg, simulating ocular pulsation. Then, IOP was changed with static steps of 1 mmHg between 20 and 30 mmHg to assess the reproducibility and linearity of the CLS. In both cases, measurements from the CLS and IOP showed very good correlation. A calibration graph shows that the CLS is capable of monitoring the IOP of each individual eye with a reproducibility of ± 0.2 mmHg (95% confidence interval). Conclusion: The wireless CLS shows a good functionality to monitor the IOP on enucleated pig eyes. The device is placed in the same way as a soft disposable contact lens. This device would allow a minimally invasive and continuous monitoring of IOP over prolonged periods of up to 24 hr, regardless of patient activity, thus opening up new diagnostic and therapeutic methods to manage glaucoma.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related concepts (32)
Intraocular pressure
Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. Most tonometers are calibrated to measure pressure in millimeters of mercury (mmHg). Intraocular pressure is determined by the production and drainage of aqueous humour by the ciliary body and its drainage via the trabecular meshwork and uveoscleral outflow.
Contact lens
Contact lenses, or simply contacts, are thin lenses placed directly on the surface of the eyes. Contact lenses are ocular prosthetic devices used by over 150 million people worldwide, and they can be worn to correct vision or for cosmetic or therapeutic reasons. In 2010, the worldwide market for contact lenses was estimated at 6.1billion,whiletheUSsoftlensmarketwasestimatedat6.1 billion, while the US soft lens market was estimated at 2.1 billion. Multiple analysts estimated that the global market for contact lenses would reach $11.7 billion by 2015.
Cataract surgery
Cataract surgery, which is also called lens replacement surgery, is the removal of the natural lens (also called the "crystalline lens") of the human eye that has developed a cataract, an opaque or cloudy area. The eye's natural lens is usually replaced with an artificial intraocular lens (IOL). Over time, metabolic changes of the crystalline lens fibres lead to the development of a cataract, causing impairment or loss of vision. Some infants are born with congenital cataracts, and environmental factors may lead to cataract formation.
Show more
Related publications (34)

A new self-adjustable glaucoma valve

Nikolaos Stergiopulos, Stéphane Bigler, Julien Maxime Gerber, Soroush Rafiei

Introduction: Glaucoma, the leading cause of irreversible blindness globally, affects more than 70 million people across the world. When initial treatments prove ineffective, especially for cases with high intraocular pressure (IOP), the preferred approach ...
Frontiers Media Sa2024

Intraocular Lens Refractive Index and Its Impact on External Surface Reflections

Georges Wagnières

PURPOSE: To determine and compare the origin of the external surface reflections produced by commonly used intraocular lenses (IOLs). METHODS: The specular reflection taking place at the anterior surface of eight types of IOLs (IOL power = 22.00 diopters M ...
SLACK INC2021

Flexure-based mecano-optical multi-degree-of-freedom transducers dedicated to medical force sensing instruments

Sebastian Krzysztof Fifanski

This thesis develops novel multi-degrees-of-freedom flexure-based force sensors by exploiting white light interferometry. Fabry-Pérot interferometry measurement has nanometric accuracy which yields sub milli-Newton force sensing accuracy. Such force sensin ...
EPFL2020
Show more

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.