To perform a current sensing in capacitorless 1-transistor (IT) DRAMs on SOI, we have developed a sensing scheme with automatic reference generation. The reference current is generated by an adjustable current source. The electrical calibration of the reference current source is performed using a digital-to-analog converter and a successive approximations algorithm. By setting the reference just below the current of the data state "1" the data retention time in the holding mode is maximized. The proposed scheme is evaluated in a 2-kb test chip implemented in a 1-mu m partially depleted (PD) SOI process. The measured retention time under holding conditions is higher than 1 s. In the continuous read mode, a few hundreds of the read cycles can be performed without a refresh operation. The test chip measures an access time of 25 ns with a read cycle time of 70 us.
Marcos Rubinstein, Farhad Rachidi-Haeri, Elias Per Joachim Le Boudec, Chaouki Kasmi, Nicolas Mora Parra, Emanuela Radici
Basil Duval, Stefano Coda, Joan Decker, Umar Sheikh, Luke Simons, Claudia Colandrea, Jean Arthur Cazabonne, Bernhard Sieglin, Gergely Papp