Experimental study on condensation heat transfer in vertical minichannels for new refrigerant R1234ze(E) versus R134a and R236fa
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
This article investigates the effect of inlet orifices on saturated critical heat flux (CHF) in multi-microchannel heat sinks. Two different multi-microchannel heat sinks made in copper were tested with three low pressure refrigerants (R134a, R236fa, R245f ...
Ieee Service Center, 445 Hoes Lane, Po Box 1331, Piscataway, Nj 08855-1331 Usa2009
New saturated critical heat flux (CHF) data have been obtained experimentally in two different multi-microchannel heat sinks made in copper with three low pressure refrigerants (R134a, R236fa, R245fa). One of the test sections had 20 parallel rectangular c ...
This article presents experimental results of heat transfer from two different studies [1, 2] for horizontal flow boiling inside smooth copper tubes with different refrigerants. The main goal of this study was to verify the influence of the saturation temp ...
The current industrial need for compact high heat density cooling devices has conveyed an increasing interest on convective boiling in micro-channels. Although there is general agreement that these systems may be able to dissipate potentially very high hea ...
An extensive experimental campaign has been carried out for the measurement of saturated critical heat flux in a multi-microchannel copper heat sink. The heat sink was formed by 29 parallel channels that were 199 mu m wide and 756 mu m deep. In order to in ...
New predictive methods for falling film condensation on vertical arrays of horizontal tubes using different refrigerants are proposed, based on visual observations revealing that condensate is slung off the array of tubes sideways and significantly affects ...
The flow pattern based flow boiling heat transfer and two-phase pressure drop models for CO2, recently developed by Cheng et al. [L Cheng, G. Ribatski. J. Moreno Quiben, J.R. Thome, New prediction methods for CO2 evaporation inside tubes: Part I - A two-ph ...
An electrically heated foil glued on top of an acrylic wall is employed to measure convective heat transfer on turbine vane platforms. The use of a heater foil requires specific filtering techniques to obtain the searched quantities – heat transfer coeffic ...
Experiments of flow boiling heat transfer were conducted in four horizontal flattened smooth copper tubes of two different heights of 2 and 3 mm. The equivalent diameters of the flattened tubes are 8.6, 7.17, 6.25, and 5.3 mm. The working fluids were R22 a ...
The present study presents new flow boiling heat transfer results of R-134a flowing inside a 13.84 mm internal diameter, smooth horizontal copper tube. The heat transfer measurements were made over a wide range of test conditions: saturation temperatures o ...